Grounding and Electrical Requirements
309477F
7
Grounding and Electrical Requirements
This sprayer requires 220-240 VAC, 50/60 Hz, 10A 
circuit with a grounding receptacle. Do not use an outlet 
that is not grounded.
Do not use the sprayer if the electrical cord has a 
damaged ground prong. Only use an extension cord 
with an undamaged 3-prong plug. 
Only use an extension cord with an undamaged 3-prong 
plug. Recommended extension cords for use with this 
sprayer are:
15 m (49.2 ft) 1.0 mm
2
30 m (88.4 ft) 1.5 mm
2
50 m (164.0 ft) 2.5 mm
2
Spray gun:
 
ground through connection to a properly 
grounded fluid hose and pump.
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code. 
Use only conductive metal pails, placed on a grounded 
surface such as concrete. Do not place the pail on a 
nonconductive surface, such as paper or cardboard, 
which interrupts grounding continuity.
Grounding the metal pail: connect a ground wire to the 
pail by clamping one end to pail and other end to ground 
such as a water pipe.
To maintain grounding continuity when flushing or 
relieving pressure: 
hold metal part of the spray gun 
firmly to the side of a grounded metal pail, then trigger 
the gun.
Thermal Overload
Motor has a thermal overload switch to shut itself down 
if overheated. 
Smaller-gauge or longer extension cords may 
reduce sprayer performance.
ti2021a
ti2022a
WARNING
To reduce risk of injury from motor starting unex-
pectedly when it cools, always turn power switch 
OFF if motor shuts down.