Haier 309292L User Manual

Page of 48
Operation
309292L
15
Operation
Low Voltage Adjustment (Smart 
Guns Only)
The ES HI/LO switch enables you to switch between full 
voltage and a lower voltage output. The lower voltage is 
factory set, but can be adjusted.
1.
Set the ES HI/LO switch to LO.
2.
Remove the LO VOLTAGE adjustment plug (53). Set 
the desired voltage, using a small screwdriver to 
slide switches 1 and 2 ON or OFF, according to 
Table 3 . Also see F
Fig. 5. Low Voltage Adjustment Switches
INSTRUCTIONS
Refer to the gun operation manual (supplied) 
for Setup, Shutdown, and Daily Care proce-
dures.
100
%
KV
μα
0
ti1529a
53
1
2
ON
OFF
Table 3: Low Voltage Adjustment
60 kV Guns
85 kV Guns
1
2
kV
1
2
kV
ON
ON
50
ON
ON
70
ON
OFF
40
ON
OFF
60
OFF
ON
35
OFF
ON
50
OFF
OFF
30
OFF
OFF
40
Factory
Setting