Installation
Install the System
. 2. shows a typical electrostatic air spray system. It 
is not an actual system design. For assistance in 
designing a system to suit your particular needs, contact 
your Graco distributor.
Warning Sign 
Mount warning signs in the spray area where they can 
easily be seen and read by all operators. An English 
Warning Sign is provided with the gun.
Ventilate the Spray Booth
Electrically interlock the gun air supply with the ventila-
tors to prevent gun operation without ventilating fans 
operating. Check and follow all National, State, and 
Local codes regarding air exhaust velocity require-
ments.
High velocity air exhaust will decrease the operating effi-
ciency of the electrostatic system. Air exhaust velocity of 
100 ft/min (31 linear meters/minute) should be sufficient.
WARNING
Fire, Explosion, and Electric Shock Hazard
Installing and servicing this equipment 
requires access to parts which may cause 
electric shock or other serious injury if work 
is not performed properly.
• Do not install or service this equipment 
unless you are trained and qualified. 
• Be sure your installation complies with 
National, State and Local codes for the 
installation of electrical apparatus in a 
Class I, Group D or a Class II 2G Haz-
ardous Location. 
• Comply with all applicable local, state, 
and national fire, electrical, and other 
safety regulations.
WARNING
Flammable or Toxic Vapor Hazard
Provide fresh air ventilation to avoid the 
buildup of flammable or toxic vapors when 
spraying, flushing, or cleaning the gun. Do 
not operate the gun unless ventilation fans 
are operating.