Graco 332458B User Manual

Page of 38
Technical Data
Positive Displacement
Proportioner
U.S.
Metric
Maximum fluid working
pressure:
AC1000 Air Spray
Systems
300 psi
2.1 MPa, 21 bar
AC2000 Air-Assisted
Spray Systems
1500 psi
10.5 MPa, 105 bar
Maximum working air
pressure:
100 psi
0.7 MPa, 7.0 bar
Air supply:
85–100 psi
0.6–0.7 MPa, 6.0–7.0 bar)
Air filter inlet size:
3/8 npt(f)
Air filtration for air logic
(user-supplied):
5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing
air (user-supplied):
30 micron (minimum) filtration required; clean and dry air
Mixing ratio range:
0.1:1 to 50:1, ±1%
Fluids handled:
one or two component:
• solvent and waterborne paints
• polyurethanes
• epoxies
• acid catalyzed varnishes
• moisture sensitive isocyanates
Viscosity range of fluid:
20–5000 centipoise
Fluid filtration
(user-supplied):
100 mesh minimum
Maximum fluid flow:
800 cc/minute (depending on material viscosity)
Fluid outlet size:
1/4 npt(m)
External power supply
requirements:
90 - 250 Vac, 50/60 Hz, 7 amps maximum draw
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
Operating temperature
range:
36 to 122°F
2 to 50°C
Storage temperature
range:
–4 to 158°F
–20 to 70°C
Weight of base model
(approximate):
195 lb
88 kg
Sound data:
Less than 75 dB(A)
Wetted parts:
17–4PH SST, 303 SST, 304 SST, Tungsten carbide (with nickel binder),
perfluoroelastomer; PTFE, PPS, UHMWPE
332458B