Graco 334466A User Manual

Page of 59
Pressure Relief Procedure
334466A
13
Pressure Relief Procedure
Follow the Pressure Relief 
Procedure whenever you see this 
symbol.
1.
Turn ON/OFF switch to OFF position. 
Wait 7 seconds for power to dissipate.
2.
Engage trigger lock.
3.
Remove tip guard.
4.
Turn pressure control to lowest setting. 
Disengage trigger lock.
This equipment stays pressurized until 
pressure is manually relieved. To help 
prevent serious injury from pressurized 
fluid, such as skin injection, splashed fluid 
and moving parts, follow the Pressure 
Relief Procedure whenever sprayer is 
stopped and before sprayer is cleaned or 
checked, and before equipment is 
serviced.
ti24586a
ti24931a
ti24592a
ti24603a