Wagner SprayTech 558054 User Manual

Page of 32
ProSpray 3.39 
11
GB
 
Starting operation
4.7 
Digital Electronic Spray Control (DESC)
The Digital Electronic Spray Control (DESC) increases the functionality 
of the sprayer.  It is installed directly below the pressure control 
knob on the control panel.  It consists of a display and four function 
keys.  The display shows various menu screens that allow the user to 
customize and monitor sprayer operation using the function keys.
SET MPa
23.0
ACTUAL MPa
22.5
Display
Function
Keys
i
The pressure control knob overrides the Digital 
Electronic Spray Control (DESC) settings.  Anytime the 
pressure control knob is turned, the sprayer pressure 
will change accordingly.
Function Keys
The function keys are numbered 1–4.  Each key is labeled with an 
additional function as well.  
#1/Menu Key
Pressing the #1 key scrolls through the available menu screens or 
performs a function described on the active menu screen.
#2/
g Key
Pressing the #2 key performs a function described on the active menu 
screen or increases a value.
#3/
h Key 
Pressing the #3 key performs a function described on the active menu 
screen or decrease a value.
#4/Select Key
Pressing the #4 key selects the active menu screen or performs a 
function described on the active menu screen.
Menu Screens
Several menu screens are available for the user to customize and
monitor sprayer operation. They include Main Screen, Volume
Pumped, Job Volume, Unit Serial #, Timers, Job Timers, Service Time,
Security Code, Prime, and Rapid Clean.
Main Screen
SET MPa
23.0
ACTUAL MPa
22.5
The Main Screen is the default screen for 
the control system at sprayer startup.  
Pressing the #2 key switches between PSI, Bar and MPa units of 
measure.  Press the #1 key to scroll through the remaining menu 
screens.
i
For sprayers equipped with an nine-language Digital 
Electronic Spray Control (DESC):
Pressing the #2 key at the Main Screen switches 
between PSI, Bar and MPa units of measure.
Current Select Screen
CURRENT SELECT
SELECT-4
MENU-1
The Current Select screen allows you to 
toggle between operating in 15 Amp or 20 
Amp mode.  
To select the Current Select screen, press the #4 key.  Pressing the 
#2 or #3 allows you to choose the desired mode.  When the screen 
displays the desired mode, press the #1 key to save and return to the 
remaining menu screens.      
Volume Pumped Screen
VOLUME PUMPED
SELECT-4
MENU-1
The Volume Pumped screen shows the
total number of gallons or liters sprayed by 
the sprayer.
GALLONS      X
MENU-1
LITRES          X
MENU-1
LITRES-2
GALLONS-2
To select the Volume Pumped screen, press
the #4 key.
job Volume Screen
JOB VOLUME
SELECT-4
MENU-1
The Job Volume screen allows the user
to reset a liter counter to track usage on 
specific jobs.
GALLONS
XXXX
RESET-3
MENU-1
To select the Job Volume screen, press the
#4 key.
unit Serial # Screen
UNIT SERIAL #
SELECT-4
MENU-1
The Unit Serial # screen shows the sprayers
serial number.
SER # XXXXXXXXXX
MENU-1
To select the Unit Serial # screen, press the
#4 key.
Timers Screen
TIMERS
SELECT-4
MENU-1
The Timers screen shows the total time the 
sprayer has been turned on as well as the 
total time the sprayer has been running (pumping).
ON TIME
RUN TIME
XXXX
XXXX
To select the Timers screen, press the #4 
key.
job Timers Screen
JOB TIMERS
SELECT-4
MENU-1
The Job Timers screen allows the user to 
reset the “ON TIME” and “RUN TIME” to
track time on specific jobs.
JOB ON
X
RESET-3
MENU-1
JOB RUN
X
RESET-3
MENU-1
To select the Job Timers screen, press the 
#4 key. “JOB ON” screen will appear. Press
#3 to reset. Press #1 to continue to “JOB
RUN” screen. Press #3 to reset. Press #1
to scroll through the remaining menu 
screens.  
Service Time Screen
SERVICE TIME
SELECT-4
MENU-1
The Service Time screen allows the user to 
set a service time interval (in hours).  Below 
the set time, the screens shows the current amount of hours on the 
sprayer since the last activation of the service timer.  To select the 
Service Timer screen, press the #4 key.
SERVICE @    XX
RUN HOURS    XX
To set the service time, press the #2 (up) 
and/or the #3 (down) keys to the desired 
time (run hours will increase/decrease in increments of 25 for each 
time you press a key).  
When the service time interval is set and met by the run hours, the 
display will show a “Service Required” screen. The pump will remain
functional.  To return to the Main Screen, press the #1 key.  Doing so 
will reset the “Service @” and “Run Hours” displayed on the Service
Screen back to 0.