Wagner SprayTech 3.31 User Manual

Page of 36
8
ProSpray 3.29 • 3.31
GB
Description of unit 
Starting operation
3.5 
Technical data
 
ProSpray 3.29 
ProSpray 3.31
Voltage: 
 220~240 Volt, 50/60 Hz
Max. current consumption: 
7.5 A 
 
8 A
Power cord: 
  3 x 1.5 mm
2
  – 6 m
Acceptance capacity: 
1725 Watt 
 
1840 Watt  
Max. operating pressure: 
  221 bar (22.1 MPa)
Volume flow at 12 MPa
(120 bar) with water: 
3,0 l/min 
 
3,8 l/min
Max tip size: 
0.029 inch –  
  0.032 inch –
 
0.73 mm 
 
0.81 mm
Max. temperature of the
coating material:
43°C
Max viscosity: 
 
25.000 mPa·s   
Weight: 
 
43.5 kg 
 
Special high-pressure hose:
DN 6 mm, 15 m, connection
thread M 16 x 1.5
Dimensions (L X W X H): 
  590 x 529 x 726 mm 
Max sound pressure level: 
 
80 dB (A) *
  *  Place of measuring: 1 m in distance from the unit and 1.6 
m above the floor, 12 MPa (120 bar) operating pressure,
reverberant floor.
3.6 
Transportation
Pushing or pulling the unit
Pull out the handle (Fig. 2, Item 1) until it will come no further. 
Insert the handle – push the buttons (2) on the spars, and then 
push in the handle.
2
1
2
3.7   Transportation in vehicle
Secure the unit with a suitable fastening.  
4. 
Starting operation
4.1 
High-pressure hose, spray gun and 
separating oil
  1.  Screw the high-pressure hose (2) to the coating material 
outlet (Fig. 3, Item 1).
  2.  Screw the spray gun (3) with the selected tip onto the 
high-pressure hose.
 3.  Tighten the union nuts at the high-pressure hoses firmly
so that coating material does not leak.
3
2
1
  4.  Remove the oil cup cap with a straight-slot screwdriver.
  5.  Fill the oil cup with EasyGlide (Fig. 4) until the oil gauge 
(4) is showing that it is full.
Attention
EasyGlide prevents increased wear and tear to 
the packings.
  6.  Replace oil cup cap.
  7.  Press oil button 2-5 times to prime the oiler.  Press once 
for every eight hours of usage to lubricate the fluid section.