Toro 41235 User Manual

Page of 159
Workman 200
Ultra Sonic Boom System (Rev. C)
Page 3.2 -- 31
Toro Electronic Controller (TEC)
The Ultra Sonic Boom System uses the Toro Electronic
Controller (TEC) to control electrical system operation.
The TEC is attached to a mounting plate under the dash
panel (Fig. 24).
Power is provided to the TEC when the vehicle ignition
switch is ON. A 2 Amp fuse provides circuit protection for
this logic power to the TEC. The fuse is located in the Ul-
tra Sonic Boom System fuse block under the dash pan-
el.
The TEC monitors the states of the following compo-
nents as inputs: the sonic boom switch, the two (2) boom
lift switches, the two (2) sonic boom sensors and the
diagnostic shunt wires.
The TEC controls electrical output to the sonic boom
light, the diagnostic lamp, the four (4) relays used to con-
trol the sonic boom system and the two (2) sonic boom
sensors. Circuit protection for the TEC outputs is pro-
vided by three (3) 7.5 Amp fuses located in the Ultra
Sonic Boom System fuse block.
Testing of the TEC inputs and outputs can be completed
with the use of the Diagnostic Display (see the Special
Tools and Troubleshooting sections of this chapter).
Because of the solid state circuitry built into the TEC,
there is no method to test it directly. The TEC may be
damaged if an attempt is made to test it with an electrical
test device (e.g. digital multimeter or test light).
IMPORTANT: Before performing welding on the ma-
chine, disconnect both cables from the battery and
disconnect wire harness connector from the TEC.
These steps will prevent damage to the machine
electrical system.
1. Dash panel
2. TEC controller
Figure 24
2
1
Figure 25
1. Mount plate
2. U--bolt clamp (2 used)
3. TEC controller
4. Nut (4 used)
5. Cap screw (4 used)
1
2
3
5
4
Ultr
a
S
onic
Boom
Sys
tem