Cleanup 
20
332919C
9. Raise siphon tube above flushing fluid and run 
sprayer for 15 to 30 seconds to drain fluid. Turn 
pump switch and engine OFF
10. Turn prime valve down DRAIN position.
11. Remove filters from gun and sprayer, if installed. 
Clean and inspect. Install filters.
12. If flushing with water, flush again with mineral spirits, 
or Pump Armor, to leave a protective coating to pre-
vent freezing or corrosion.
13. Wipe sprayer, hose and gun with a rag soaked in 
water or mineral spirits.
ti22731a
ti14842a
ti15018a
ti2776a