Grizzly G0632 User Manual

Page of 56
G0632 16" x 42" Variable Speed Wood Lathe
-37-
Review the troubleshooting and procedures in this section to fix or adjust your machine if a problem devel-
ops. If you need replacement parts or you are unsure of your repair skills, then feel free to call our Technical 
Support at (570) 546-9663. 
SECTION 7: SERVICE
Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Machine  does  not 
start  or  a  breaker 
trips.
1.  Emergency  stop  push-button  is  engaged/
faulty.
2.  Motor connection wired incorrectly.
3.  FWD/REV switch is at fault.
4.  Speed rotary switch is at fault.
5.  Wiring is open/has high resistance.
6.  Motor is at fault.
7.  Frequency inverter is at fault.
1.  Rotate clockwise slightly until it pops out/replace it.
2.  Correct motor wiring connections.
3.  Replace faulty FWD/REV switch.
4.  Replace bad speed rotary switch.
5.  Check  for  broken  wires  or  disconnected/corroded 
connections, and repair/replace as necessary. 
6.  Test/repair/replace.
7.  Replace.
Machine  stalls  or  is 
underpowered.
1.  Feed rate/cutting speed too fast for task.
2.  Belt slipping.
3.  Motor connection is wired incorrectly.
4.  Pulley slipping on shaft.
5.  Motor bearings are at fault.
6.  Machine is undersized for the task.
7.  Motor has overheated.
8.  Speed rotary switch at fault.
9.  Motor is at fault.
1.  Decrease feed rate/cutting speed.
2.  Replace bad belt and re-tension (see 
Page 38).
3.  Correct motor wiring connections.
4.  Replace loose pulley.
5.  Test by rotating shaft; rotational grinding/loose shaft 
requires bearing replacement.
6.  Use  sharp  lathe  bits  and  chisels;  reduce  the  feed 
rate/depth of cut.
7.  Clean off motor, let cool, and reduce workload.
8.  Replace bad speed rotary switch.
9.  Test/repair/replace.
Machine  has  vibra-
tion  or  noisy  opera-
tion.
1.  Motor or component is loose.
2.  Belt worn or loose.
3.  Motor fan is rubbing on fan cover.
4.  Pulley is loose.
5.  Machine  is  incorrectly  mounted  or  sits 
unevenly on floor.
6.  Motor mount loose/broken.
7.  Workpiece, center, or faceplate is at fault.
8.  Motor bearings are at fault.
1.  Inspect/replace stripped or damaged bolts/nuts, and 
re-tighten with thread locking fluid.
2.  Inspect/replace belts (see 
Page 38).
3.  Replace  dented  fan  cover;  replace  loose/damaged 
fan.
4.  Replace  shaft,  pulley,  setscrew,  and  key  as 
required.
5.  Tighten/replace anchor studs in floor; relocate/shim 
machine.
6.  Tighten/replace.
7.  Center  workpiece  in  center  or  faceplate;  reduce 
RPM; replace defective center or faceplate.
8.  Test by rotating shaft; rotational grinding/loose shaft 
requires bearing replacement.
Troubleshooting