Bosch FNS250-16 User Manual

Page of 42
3.
Disconnect  the  tool  from  the  air  source  before  making
adjustments,  clearing  jams,  unloading  fasteners,
leaving  the  work  area,  performing  tool  maintenance  or
storing  the  tool.  
Such  precautionary  safety  measures
reduce the risk or unintentional tool operation.
Never carry the tool by the hose. The tool, air fittings and
the air hose may become damaged.
Use  clamps  or  another  practical  way  to  secure  and
support  the  work  piece  to  a  stable  platform. 
Holding
work by hand or against your body is unstable and may lead
to loss of control or personal injury.
The correct pressure is the lowest pressure that will do
the  job. 
Always  follow  recommendations  for  the  particular
tool.
Maintain  tools  with  care. Properly  maintained  tools  are
less  likely  to  break  and  cause  injury.  Any  alteration  or
modification  is  a  misuse  and  may  result  in  a  dangerous
condition.
Service
Maintenance performed by unauthorized personnel may
result  in  misplacing  of  the  internal  components  which
could  cause  serious  hazard. 
We  recommend  that  all  tool
service be performed by a BOSCH factory service center or
authorized BOSCH service station.
Develop a periodic maintenance schedule for your tool.
When cleaning a tool be careful not to disassemble any
portion  of  the  tool  since  internal  components  may  be
misplaced  or  safety  components  may  be  improperly
mounted. 
Certain cleaning agents such as gasoline, carbon
tetrachloride,  ammonia,  etc.  may  damage  plastic  parts  and
o-rings.
When  servicing  the  tool,  use  only  recommended
BOSCH  replacement  parts.  Follow  instructions  in  the
Maintenance section of this manual. 
Use of unauthorized
parts or failure to follow Maintenance Instructions can cause
a risk of injury.  
Use only the air tool lubricants supplied with the tool or
specified  by  BOSCH. 
Do  not  use  other  lubricants  as  they
may damage the tool. See the "Lubrication" section for a list
of recommended air tool lubricants.
Replace  missing  or  damaged  warning  labels. Refer  to
tool schematic for correct placement and part number.
Keep the tool clean and lubricated. Clean the tool at least
daily  and  lubricate  as  required.  Never  operate  a  dirty  or
malfunctioning tool.
When not in use, store the tool out of reach of children
and  other  personnel  unfamiliar  with  tool  operation.
When  not  in  use,  the  tool  should  be  disconnected  and
stored  in  a  dry  place.  Keep  out  of  reach  of  children.  Lock
the storage area. Tools are dangerous in the hands of users
unfamiliar with the tool. 
Air Source
Never  use  oxygen  or  other  bottled  gases  as  a  power
source. 
Explosion may occur. Combustible gases and other
bottled  gases  are  dangerous  and  may  cause  the  tool  to
explode.
Use  only  clean,  dry,  regulated,  compressed  air  within
the  rated  pressure  range  marked  on  the  tool.  Do  not
exceed  maximum  recommended  air  pressure  marked
on the tool. 
Verify prior to using the tool that the air source
has  been  adjusted  within  the  rated  air-pressure  range.  Be
sure the air pressure gauge is operating properly and check
it  at  least  twice  a  day.  Tools  operated  in  excess  of  their
maximum pressure rating may operate abnormally or burst,
resulting in personal injury.
Never connect the tool to an air source that is capable
of producing air pressure exceeding 200 PSI. 
Excessive
pressure can cause abnormal operation or cause the tool to
burst, resulting in personal injury.
Do not abuse the air hose. Protect all hoses from kinks,
restrictions,  solvents  or  sharp  objects.  Keep  air  hose
away  from  heat,  oil,  sharp  edges  or  moving  parts.
Replace damaged hoses immediately. Damaged hoses can
burst or whip around.
Check  all  fittings,  hoses,  pipes,  connections  and
compressor  before  each  use  of  this  tool.  Repair  or
replace  damaged  or  leaking  hoses  and  connections
immediately. 
Damage to a hose or connection can cause a
pressure hose to break and whip around the work area, and
can lead to injury.
Safety Rules for Pneumatic Nailer Tools
Always  assume  the  tool  contains  nails. Check  the
magazine  for  nails  that  may  be  left  in  the  tool,  even  if  you
think the tool is empty or disconnected.
Never  point  the  tool  at  yourself  or  others  in  the  work
area.  
Always  assume  the  tool  contains  nails.  If  nails  are
accidentally fired, it may result in injury. The tool is not a toy
and should not be used like one.
Remove  finger  from  the  trigger  when  not  driving  nails.
Always carry the tool by the handle only. 
Removing your
finger  from  the  trigger  when  not  operating  the  tool  reduces
the risk of unintentionally firing a nail and injuring yourself or
someone else.
Do  not  disable  or  remove  the  work  contact  element.
This  tool  is  equipped  with  a  safety  mechanism,  the  work
contact  element,  to  reduce  the  risk  of  accidental  firing.
Disabling this component can result in unintentional firing.
Do not use the tool unless the work contact element is
working  properly. 
If  the  work  contacting  element  is  not
functioning correctly, the tool can fire unexpectedly.
Never  use  non  relieving  couplers  and/or  female  quick
disconnect couplings on the tool. 
Non relieving couplings
and  female  couplings  will  trap  high  pressure  air  in  the  tool
when  the  air  line  is  disconnected.  This  will  leave  the  tool
charged  with  enough  air  after  it  has  been  disconnected  to
drive  a  nail.  Only  MALE  pneumatic  type  air  connectors
should  be  fitted  to  the  tool,  so  that  high  pressure  air  in  the
tool  is  vented  to  atmosphere  as  soon  as  the  air  line  is
disconnected.  
BM 2610957380 02-09:BM FNS250-16 06-09  6/17/09  8:05 AM  Page 3