Strong Enterprises 48057 User Manual

Page of 43
PREFACE
THE STRONG XENON TROUPER, Type 48057, is a direct current follow spotlight com-
plete with a xenon lamphouse, power supply, optical system, base and yoke assembly, and color boomerang.  It
utilizes proven design features of the Strong Xenon Super Trouper combined with advanced properties of the
Strong Super Trouper II.  Using a 700 watt xenon bulb as a light source, the Xenon Trouper meets or exceeds
all professional requirements for short- to medium-throw follow spotlight applications.
ONLY THE SPECIAL XENON POWER SUPPLIES manufactured by Strong International
can be used with the xenon spotlight.  For installation and operation of the power supply, see the manual
furnished separately.
THE XENON LAMPHOUSE utilizes a deep ellipse dichroic (“cold”) coated metal reflector
designed to operate in a fixed position with a horizontally mounted xenon bulb as the light source.  The dichroic
reflector coating reduces heat at the aperture and optical system.
BULB ADAPTERS, required to mount the 700 watt bulb into the lamphouse, are included in
the spotlight accessory kit.  Two anode adapters are supplied; the 65259 adapter, measuring 2-5/8 inches in
length, is used with the Hanovia XH0700HS bulb, and the shorter 65199 adapter is used with the OSRAM
XBO700W/HS OFR bulb.
ADJUSTMENT CONTROL for positioning the xenon bulb is located at the rear of the lamp-
house.  The adjustments are for the horizontal and vertical positioning, and focus control, of the bulb.
THE LAMPHOUSE INSTRUMENT PANEL is equipped with an ammeter and running time
meter.  The ammeter indicates the operating current of the lamp, and the running time meter records the number
of hours the lamp has operated.
THE BULB is ignited and extinguished by use of the LAMP switch mounted on the instrument
panel.  A DC Pulse Igniter Assembly requires no AC control circuit; it operates from DC open circuit voltage
normally generated by the xenon power supply.  Remote ignition switching is accommodated by wiring a dry
contact across wires 3 & 6.  See the Interconnection Wiring Diagram.
THE LAMP BLOWER, internally wired in the lamp, operates on 115 V.AC and is required to
keep the seals on the bulb at a safe operating temperature.  This blower will operate continuously until power is
turned off at the main line switch to the xenon power supply.
THE LAMPHOUSE is supplied with a 13 foot cable containing the two DC leads, the ground
lead, and all AC control leads.  The cable terminates in a multiple pin MS connector to mate to the receptacle on
the power supply.
WHEN TRANSPORTING the spotlight, it is recommended that the xenon bulb be removed
and placed in its original shipping carton with the cover on the bulb to insure against breakage.
XTR/001