Pioneer PX-42VP5 User Manual

Page of 82
 
 
28 
23. H.POSITION Gain Data
 
Function 
The  external  control  equipment  changes  the  H.  POSITION  gain  data  of  the 
plasma monitor. 
Transmission Data 
  DFH   80H   60H   7FH   03H   DATA00   DATA01    DATA02   CKS 
 
DATA00 : USER PICTURE Gain Flag   
03H 
 
DATA01 : H.POSITION Gain Flag     
02H 
 
DATA02 : H.POSITION Gain   
 
80H : -128 
 
 
 
  : 
 
 
FFH : -01 
 
 
00H : 0 
 
 
01H : +01 
 
 
  : 
 
 
7FH : +127 
ACK 
  7FH   60H   80H   7FH   02H   DATA00    DATA01   CKS 
 
DATA00: USER PICTURE Gain Flag   
03H 
 
DATA01: H.POSITION Gain Flag     
  02H 
 
 
24. V-HEIGHT Gain Data
   
Function 
The external control equipment changes the V-HEIGHT gain data of the plasma 
monitor. 
Transmission Data 
  DFH   80H   60H   7FH   03H   DATA00   DATA01    DATA02   CKS 
  DATA00 : USER PICTURE Gain Flag   
03H 
  DATA01 : V-HEIGHT Gain Flag    
07H 
  DATA02 : V-HEIGHT Gain   
 
00H : 0 
 
 
  : 
 
 
40H : +64 
ACK 
  7FH   60H   80H   7FH   02H   DATA00   DATA01    CKS 
 
DATA00: USER PICTURE Gain Flag   
03H 
 
DATA01: V-HEIGHT Gain Flag   
 
   
07H