49 
50. D-SUB INPUT
 
Function 
The external control equipment sets the D-SUB SELECT of the plasma monitor. 
Transmission Data 
  DFH   80H   60H   8DH   01H   DATA00 CKS 
 
DATA00 : D-SUB INPUT 
01H : RGB 
 
02H : SCART3(*:Only Europe can be chosen.) 
 
ACK 
The  plasma  monitor  returns  the  following  ACK  when  setting  the  D-SUB 
SELECT: 
  7FH   60H   80H   8DH   01H   DATA00 CKS 
 
DATA00 : D-SUB INPUT 
01H : RGB 
 
02H : SCART3(*:Only Europe can be chosen.) 
 
 
 
 
51. TIMER SWITCH
 
Function 
The  external  control  equipment  sets  the  timer  reservation  of  the  plasma 
monitor. 
Transmission Data 
      DFH    80H    60H    02H    01H    DATA00    CKS 
      DATA00: 
00H : Reservation OFF 
                         
01H : Reservation ON 
ACK 
      7FH    60H    80H    02H    01H    DATA00    CKS 
      DATA00: 
00H : Reservation OFF 
                         
01H : Reservation ON