61. POWER DELAY ON(at 4 or 9 multiscreen)
 
Function 
External  control  apparatus  attaches  a  time  lag  to  two  or  more  plasma 
monitors, and turns on a power supply. 
Transmission Data 
   
DFH 80H 60H F2H 01H DATA00 CKS 
     
DATA00:   00H-FFH: Delay time (second) 
 
*:  This  command  is  premised  on  two  or  more  plasma  monitor  system 
composition being multi-systems. In command issue of master
1
 OSD operation, 
the value of DATA00 is 01H (1 second). This command does not have ACK for 
one-way traffic. 
 
*1: “Master” means the 1st set of PDP at the time of cable connection at 
the time of AUTO ID execution.     
 
62. POWER DELAY ON (at 16 or 25 multi screens)
 
Function 
External control apparatus attaches a time lag to 10 or more plasma monitors, 
and turns on a power supply. 
Transmission Data 
DFH 80H 60H F6H 01H DATA00 CKS 
     
DATA00:   01H 
mode1 
 
 
02H 
mode2 
ACK 
 
7FH    60H    80H    F6H    01H    DATA00    CKS
 
     
DATA00:   01H 
mode1 
 
 
02H 
mode2 
 
 
 
NOTE: When multi mode is 16 or 25, this function is available.