49. MODEL NAME Request
 
Function 
The  external  control  equipment  inquires  the  product  code  of  the  plasma 
monitor. 
Transmission Data 
  1FH   80H   60H   17H   00H   CKS 
ACK 
The plasma monitor returns the following ACK: 
  7FH   60H   80H   17H   0CH   DATA00 to DATA11    CKS 
 
DATA00 : 1st character of the product code 
 
DATA01 : 2nd character of the product code 
 
 
 
 
DATA11 : 12th character of the product code 
 
          Received data   
 
00H-09H  : 0-9 
                   
 
 
80H 
: - (Hyphen) 
81H 
:    + 
82H 
:     
83H 
:    / 
84H 
:    ( 
85H 
:    ) 
86H 
:    . 
87H 
:    ‘
 
 
 
 
96H 
: (Blank) 
                   
 
 
10H-29H  : A-Z 
 
Corresponding 
character 
Received data (H)  10  11  12  13  14  15  16  17  18  19 
 
Corresponding 
character 
Received data (H)  1A  1B  1C  1D  1E  1F  20  21  22  23 
 
Corresponding 
character 
Received data (H)  24  25  26  27  28  29 
   
If there are fewer than 12 characters in the product code, product code