Pioneer PX-42VM5 User Manual

Page of 82
 
 
60 
58. AUTO ID SET START
 
Function 
External  control  apparatus  sets  up  ID  automatically  to  two  or more plasma 
monitors. 
Transmission Data 
    5FH 80H 60H F0H 01H DATA00 CKS 
    DATA00   
00H~FFH: ID of a master
*1
 is set up. 
 
*:  When  you  use  it  by  the  multi-system,  please  remove  the  link  input  of  a 
master
*1
.
 
 
*1: “Master” means the 1st set of PDP at the time of cable connection at 
the time of AUTO ID execution.   
 
 
59. PLE LINK 
Function 
External control apparatus sets up equally PLE between two or more plasma 
monitors. 
Transmission Data 
    DFH 80H 60H F1H 03H DATA00 to DATA02 CKS 
DATA00  00H:PLE LINK ON 
01H:PLE LINK OFF   
DATA01   FFH   
DATA02   FFH 
*: This command is premised on the system configuration of two or more plasma 
monitor  being  a  multi-system.  When  renewal  of  the  PSC  data  based  on  this 
command  is  not  carried  out  during  a  certain  fixed  period  (about  2  seconds) 
during  PLE  LINK  enforcement,  each  plasma monitor  sets  PSC  data  as  FFH. 
Since this command is one-way traffic, there is no ACK. 
*DATA01:  Please  set  up  FFH, when you publish  this  command  from  external 
control apparatus.  A master
*1
  sets up its own PSS data. As compared with its 
own PSS data, the plasma monitor after the master that received this command 
sets up the data of the larger one, and equips the output of a command with it. 
*DATA02:  Please  set  up  FFH, when you publish  this  command  from  external 
control apparatus. The 1st round which PSS data has not decided is FFH. 
 
*1: “Master” means the 1st set of PDP at the time of cable connection at