BEA LO-21P User Manual

Page of 13
75.5079.08 20061129 
 
Page 13 of 13 
 
BODYGUARD
DK-12
DATA +  7
D
A
T
A
 -   6
N
.C
.        5
N
.O
.        4
C
O
M
       3
POWER 2
POWER 1
5 N/C
4 N/O
3 COM
2 PWR
1 PWR
SIZE:
SHEET:
SCALE:
A  
PH: (412) 249-4100    FAX: (412) 249-4101
B.E.A., Inc.
100 Enterprise Drive    Pittsburgh, PA  15275
DATE:
www.beasensors.com
CAGE CODE:
D
WG NO:
FILE OF:
DRAWN BY:
REV:
1 OF 1
NTS
T
IT
L
E
: BESAM CUP VER. 6.3,6.4 CONT
ROL
 
            WITH LO-21P PARALLAX II SYSTEM
            Q-DISCONNECT ON SAFETY SIDE
22 SEPT 2003
JED
B
80.0194
RE
D
BL
AC
K
WH
IT
E
BL
AC
K
RE
D
8 P
OW
ER
7 P
OW
ER
6 C
OM
5 N
.O
.
4 N
.C
.
3 I
NH
IB
IT
 +
2 I
NH
IB
IT
 G
ND
1 B
LA
NK
8 P
OW
ER
7 P
OW
ER
6 C
OM
5 N
.O
.
4 N
.C
.
3 I
NH
IB
IT
 +
2 I
NH
IB
IT
 G
ND
1 B
LA
NK
8 P
OW
ER
7 P
OW
ER
6 C
OM
5 N
.O
.
4 N
.C
.
3 I
NH
IB
IT
 +
2 I
NH
IB
IT
 G
ND
1 B
LA
NK
8 P
OW
ER
7 P
OW
ER
6 C
OM
5 N
.O
.
4 N
.C
.
3 I
NH
IB
IT
 +
2 I
NH
IB
IT
 G
ND
1 B
LA
NK
BL
AC
K
RE
D
LO-21P
WHITE
GRAY
VIOLET
BLACK / WHITE
LEFT APPROACH SIDE
LEFT SAFETY SIDE
RIGHT SAFETY SIDE
RIGHT APPROACH SIDE
WH
IT
E
RE
D
BR
OW
N
BL
AC
K
GR
EE
N
GR
EE
N
YE
LL
OW
YE
LL
OW
BR
OW
N
EAGLE
H
O
L
D
 OPEN
OFF
AU
T
O
Tech Support
NO
T US
E
D
NO
T US
E
D
NO
T US
E
D
NO
T US
E
D
BLACK --
RED +
18  -24 VDC
17  +
2
4 VDC
19  +
1
8 VDC
14  SWITCH 2 
13  SWITCH 1
12  SYNC
11  0 VDC 
10  SYNC
8    OFF
9    MAT
5   P DET
4   COM
3   I IMP
C
U
P
S
L
A
V
E
C
U
P
M
A
S
T
E
R
14  SWITCH 2
18  -24 VDC
17  +
24 VDC
19  +
18 VDC
13  SWITCH 1
SYNC        12
0 VDC        11
SYNC        10
OFF             8
9   MAT LOGIC
5   P DET
4   COM
3   I IMP
NOTE:  
       1.) REM
O
VE FROM
 PIN 6 AND PLACE A WIRE NUT ON THE 
            APPROACH SIDE SUPERSCAN'S WHITE WIRE.
            INST
ALL T
H
E YELLO
W WIRE INT
O
 PIN 6. 
       2.) THE BODYGUARD RELAY OUTPUT FUNCTION
            M
U
ST
 BE CHANG
ED T
O
 #2.
       3.) DO NOT POWER ALL THE SENSORS FROM
 ONE
            CO
NT
RO
L BO
X .
       4.) ON BOTH 
CONTROLS SET 
PMD FUNCTIONS 
            20=b, 19=b, 18=00, 17=00, 14=a, 13=a, 12=65
            DEGREES, 11= 5 DEGREES LESS THAN F10
       5.) INHIBITING THE SAFETY SIDE SUPERSCAN (F12)
            SHOULD OCCUR AT APPROX. 65-75 DEGREES.
SYNC CABLE
RED/WHITE
SUPERSCAN QUI
C
K
DI
SCONNECT CABLE
SUPERSCAN QUI
C
K
DI
SCONNECT CABLE
(See Note #2)
(See Note #1)
(See Note #1)
GREEN
BLUE
- ORANGE
+ BROWN