General Troubleshooting 
 
Symptom 
Possible Cause(s) 
Possible Action(s) 
General low light intensity 
Dirty LEDs 
Clean the MotionDrape™ LED drape regularly  
One LED in an LED group 
failed 
Faulty (shorted) LED 
Replace faulty LED  
All the LEDs in a group 
failed 
Faulty (open) LED 
Replace faulty LED 
Faulty LED cable 
Replace faulty LED cable 
Faulty LED driver 
Replace faulty LED Driver box  
Single MotionDrape™ LED 
controller: All LEDs in a 
drape failed 
Faulty LED driver box 
Replace faulty LED Driver box 
Faulty drape output cable  
Repair or replace faulty cable 
Faulty MotionDrape™ LED controller 
Replace MotionDrape™ LED controller 
Multiple MotionDrape™ LED 
controllers: All LEDs on a 
controller failed 
Faulty MotionDrape™ LED controller 
Replace MotionDrape™ LED controller 
If using DMX connection, wrong DMX address 
on the corresponding controller 
Set the starting DMX address correctly 
If using proprietary serial link, wrong 
Master/Slave setting on the corresponding 
controller 
Set the starting Master/slave mode correctly 
MotionDrape™ LED controller not powered 
Check power to the MotionDrape™ LED 
controller 
Faulty DMX cable 
Repair or replace faulty cable 
Breaker/Fuse keeps blowing 
Excessive circuit load 
Check total load placed on the electrical circuit 
Short circuit along the power wires 
Check for a short in the electrical wiring (internal 
and/or external) 
MotionDrape™ LED 
controller does not power 
up 
No power 
Check for power on Mains 
Faulty or lose power cord 
Check power cord 
Faulty internal power supply 
Replace internal power supply 
Product is not responding to 
DMX 
Wrong DMX addressing 
Check DMX controller and product addressing 
Wrong polarity on the controller 
Check polarity switch settings on the controller 
Lose or damaged cables 
Check DMX and signal patch cables 
Faulty Main PCB 
Replace Display PCB 
Loss of signal on some 
MotionDrape™ LED 
controllers 
Non compatible signal patch cables 
Use only compatible cables 
Bouncing signals 
Install terminator as suggested 
Long cable / Low level signal 
Do not exceed maximum recommended length 
Too many products 
Install an optically coupled DMX splitter after unit 
#32. 
Interference from AC wires 
Keep DMX and signal patch cables separated 
from power cables or black lights 
 
 
If you still experience problems after trying the above solutions, contact 
CHAUVET® Technical Support.