Furuno DS-80 User Manual

Page of 40
 
14 
3 MAINTENANCE, TROUBLESHOOTING
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
Only qualified personnel
should work inside the
equipment.
 
3.1 Maintenance 
3.1.1 Preventive maintenance 
Check the following points regularly to 
maintain performance. 
• 
Check that the connectors on all units of 
the system are firmly fastened and free of 
rust. Clean if soiled or corroded. 
• 
Check that all ground wires are tightly 
fastened. 
• 
Dust and dirt on the display unit including 
the screen may be removed with a soft 
cloth. Do not use chemical cleaners to 
clean the display unit; they can remove 
paint and markings. 
3.1.2 Transducer maintenance 
Marine life (barnacles, etc.) adhering to the 
transducer face will reduce sensitivity. 
Periodically remove any marine life from 
the transducer face with fine sandpaper or 
a piece of wood. 
   
 
CAUTION
Do not paint the transducer.
Painting will affect performance.
 
3.1.3 Fuse replacement 
Fuses in the units of the system protect the 
electrical circuitry from burning by 
overcurrent. If the equipment cannot be 
energized check the fuse in the power 
cable connected to the display unit. Locate 
the cause before replacing the fuse. 
Unit 
Rating,
Qty 
Type, 
Code No. 
Location 
Display 
Unit 
1A, 
2 pcs. 
FGMB 1A 
125 VAC, 
000-114-8
05 
Fuse 
holder in 
power 
cable 
Distribution 
Box 
3A, 
2 pcs. 
FGBO 3A 
250 VAC 
000-549- 
021 
Transceiver 
Unit 
1A, 
2 pcs. 
FGBO 1A 
250 VAC, 
000-549- 
019 
Inside 
unit 
CAUTION
Use the proper fuse.
Use of a wrong fuse can cause fire or
equipment damage and void the warranty.