Schematic diagrams 
IEC61162 RX port 
DS-801
65P6010
11
12
.
.
.
.
.
.
TB3
F2047A-20P-B
IEC61162_RX_A
IEC61162_RX_B
<11<
<12<
JP6
ERJ_6GEY0R00V
R121 22
Ω
 
   R122 120
Ω
R123 120 
Ω
R124 22
Ω
1
2
CR17  1SS181
4
5
6
1
3
JP7
ERJ_6GEY0R00V
PC400
U42
 
Load requirements as listener 
Isolation: Optocoupler 
Input Impedance: 44 ohms 
Max. Voltage: ±2.6V 
Threshold: 4 mA 
IEC61162 TX1 port 
 
Output drive capability 
Max. 20 mA