Moyer Diebel MH-60M5 User Manual

Page of 76
69
HEATERS 
OUTPUT
LEDs
WASH
EXTENDED 
WASH
T10
RINSE
FILL
T9
FLOAT 
SWITCH
LAMP 
OUTPUT
JB2
T6
T5
FUSE 1A
T7
T8
DOOR 
SWITCH
START 
SWITCH
T2
T
F
WASH 
OUTPUT
RINSE 
OUTPUT
JB1
JB3
POWER
LED
T4
T3
5 X 20 MM
FAST ACTING
CLOSED JUMPER SHOWN FROM SIDE
PRINTED CIRCUIT BOARD
BLACK JUMPER SHOWN CLOSED.
LIFT & REMOVE TO OPEN.
WHITE BASE
   MH6N, MH6O             UP TO D3857        112676 REVC          OPEN          OPEN      CLOSED
   MH6N, MH6O             D3858 - UP             113597 REVG        CLOSED      OPEN      CLOSED
        MH6L                           ALL                   113597 REVG          OPEN         OPEN      CLOSED
         MODEL             SERIAL NUMBER    PART NUMBER          JB1             JB2             JB3
                             MACHINE                    BOARD                      JUMPER SETTINGS
! ATTENTION - VERY IMPORTANT ! - 
VERIFY CIRCUIT BOARD 
PART NUMBER AND JUMPER POSITION SETTINGS (JB1, JB2, JB3) PER 
MACHINE MODEL AND SERIAL NUMBER AS INDICATED IN TABLE 
BELOW. IMPROPER JUMPER SETTINGS MAY CAUSE ERRATIC 
OPERATION.
H
H
TSHC
WASH TANK THERMOSTAT
11
BOOSTER TANK THERMOSTAT
TSBC
LINE:120V TRANSFORMER
T1
RINSE WATER VALVE
RWV
MAIN POWER SWITCH
MPS
CYCLE LIGHT
LT2
POWER ON LIGHT
LT1
CYCLE SELECT JUMPER
JB3
CYCLE SELECT JUMPER
JB2
RINSE TIME SELECT JUMPER
JB1
TANK HEAT HIGH LIMIT
HCHL
TANK HEAT CONTACTOR OR STEAM VALVE
HC1
TRANSFORMER FUSES
FUT
TANK HEAT FUSES
FUH
FLOAT SWITCH
FSW
TIMER BOARD FUSE
F1
DOOR SAFETY SWITCH, SIDE DOORS
DS2
DOOR SAFETY SWITCH, FRONT DOOR
DS1
BOOSTER TANK HIGH LIMIT
BCHL
BOOSTER TANK CONTACTOR OR STEAM VALVE
BC1
WASH MOTOR OVERLOAD
1MOL
WASH MOTOR CONTACTOR
1M
DOOR SWITCH RELAY
1CR
1MTR
WASH MOTOR
EW
EW
EXTENDED WASH SWITCH
2CR
RINSE AID SIGNAL RELAY
PER LOCAL ELECTRICAL CODE
GND
TSHC
TSBC
BC1
HC1
DS2
1M
BCHL
RWV
T1
DETERG.
SIGNAL
RINSE
SIGNAL
1MOL
T1 NOT USED WITH 
115V LINE SUPPLY
SEE NOTE 1
NOTE 1: IF SUPPLY IS 115V, T1 IS NOT USED. WIRES #1 AND 2 
ARE CONNECTED TO THE FUSE BLAOCK IN PLACE OF #39 AND 
40.
NOTE 2: USED ON MACHINES WITH INDEPENDENT FRONT 
DOOR OPTION.
STEAM/ELECTRIC - 1 & 3 PHASE
MH-6/0/L/N-E ELECTRONIC CONTROL
701602
H
NONE
J.NEWTON
20MAY99
1
1
FSW
DOORS CLOSED
TANKS EMPTY
POWER OFF
DIAGRAM STATE
END OF CYCLE
LT1
6
DS1
1MTR
28
1M
27
29
28
27
ELECTRIC TANK HEAT IF USED
FUH
HC1
4.7KW
FUH
HC1
HC1
FUH
BC1
BC1
ELECTRIC BOOSTER HEAT IF USED (SEE NOTE 3B)
BC1
NOTE 3:
   A: ON 115V MACHINES THE WASH TANK HEATER IS 3 kW.
   B: THE kW RATING OF THE BOOSTER ELEMENT IS DEPENDENT UPON THE 
VOLTAGE AND DEGREE RISE OF THE SYSTEM. SINGLE PHASE MACHINES W/ 
ELEC. BOOSTER ARE 40° RISE ONLY. 40° RISE UNITS USE 7.5/10 OR 9 kW 
ELEMENTS. 70° RISE UNITS USE 13.5/18 OR 17.7 kW ELEMENTS.
1
2
2
2
4
4
5
10
13
16
22
17
19
21
20
14
30
33
31
34
32
35
34
31
30
33
32
31
30
33
34
35
L1
36
37
L2
L1
L2
L3
38
37
36
36
37
38
L3
L2
L1
L1 L2 L3
L1 L2 L3
1M
1MOL
1MTR
(IF USED)
FUT
FUT
40
39
ON SINGLE PHASE 
MACHINES OMIT L3.
ON SINGLE PHASE 
MACHINES OMIT L3.
L3
L2
L1
L1
L2
L3
L3
L1
L2
L2
L1
L1
L3
L2
L1
L2
2
SEE NOTE 2
1CR
1CRA
9
1CRB
1CRC
12
15
2CR
1M
2CRA
23
41
24
25
24
25
26
ELECTRIC HEAT ONLY
120V FAN SIGNAL
TO CONTACTOR COIL
SUPPLIED BY OTHERS
IF USED
43
4
TO TEST INPUTS T7, T8, T9, AND T10 A METER CAPABLE 
OF READING DC VOLTAGES MUST BE USED.
1.) SET METER TO READ DC VOLTAGE
2.) PLACE BLACK LEAD TO T2
3.) PLACE RED LEAD TO TERMINAL BEING TESTED
   i.e. PLACE RED LEAD TO T8 TO TEST DOOR SW.
4.) AN OPEN SWITCH WILL READ 4.7-5.3VDC
   A CLOSED SWITCH WILL READ 0-1VDC
G
JAM
17MAR03
ADDED ACR SUPPRESSORS
ADDED TROUBLESHOOTING REFERENCES
B
4NOV99
JCN
LT1
REDRAWN MAIN POWER SWITCH
C
7MAR00
JCN
MPS
ON
OFF
1MOL
50
50
COIL
COMMON
NORMALLY OPEN
NORMALLY CLOSED
RELAY
D
REVISED SINGLE PHASE MOTOR OVERLOAD AND TANK HEAT HI LIMIT
9AUG00
JCN
4.7KW
4.7KW
HCHL
18
E
CHANGED TANK HEATER KW
30AUG02 WB
SEE NOTE 3A
4
ADD JUMPER / SN INFORMATION. 
F
1 NOV02 MJM
AS
AS
ARC SUPPRESSOR
G
ADD ARC SUPPRESSOR TO 1CR 
04MAR03 JAM
CORRECTED JB1 SETTING, CLOSED SETTING WAS OPEN
H
2/3/04
WB
BY
DATE
DESCRIPTION
REV.
B
REV.
REV.
DESCRIPTION
DATE
BY
CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz,
AS SPECIFIED PER ORDER,TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION POINT
MUST COMPLY WITH ALL LOCAL ELECTRIC CODES.
SCALE
DR.BY
DATE
SHEET
OF
12
9
13
14
5
1
8
4
AS
AS