4.1.2  Setup of Scan Module 
The following dialog is for setting DVPDNET-SL’s current mode: master mode or slave mode. 
 
 
Parameter 
Explanation 
Master 
mode 
For setting DVPDNET-SL as master mode. 
Scan 
interval 
time 
The cycle time for master to send and receive the real time data after real-time 
data connection is successful. 
Timeouts  
EPR) 
The result value of the parameter multiplied by 4. (Unit:ms) 
Master assumes that the slave is offline if it receives no response from slave after 
timeout. 
Extended 
baud rate 
The parameter gets effective only in master mode. 
Selecting “Startup” activates the function of extended baud rate. 
Select the appropriate baud rate according to actual demand then. 
Slave mode  For setting DVPDNET-SL as slave mode 
Bit-strobe  Reserved; no actual purpose now. 
Polled 
The parameters get effective only in slave mode. 
The filled byte number corresponds to the data length for output and input as 
DVPDNET-S is taken as slave. “Sending data length” corresponds to “Output 
length” and “Receiving data length” corresponds to “Input length”. 
COS/CC 
Reserved; no actual purpose now. 
Device 
mapping 
address 
For AH modes specially; no actual purpose now. 
Note: These parameters and the configuration information are downloaded to DVPDNET-SL together.   