4 Temporarily enable strict authentication in ETEMS and make sure that you can still communicate 
with the PEPs (refresh status for the PEPs that you used in step 3. If the PEPs respond appropriately, 
continue with the next step. If you cannot communicate with the PEPs, troubleshoot and fix the 
problems found.
5 If step 4 was successful, enable strict authentication on the PEPs that you used in step 3 and retest 
communications. If ETEMS can still communicate with the PEPs, then ETEMS has certificates that 
can be used.
At this point, you can disable strict authentication and continue to provision more of the network. 
6 When you have installed certificates on all of the devices in the system (including the ETKMSs and 
all of your PEPs), you can reenable strict authentication in ETEMS. 
7 Refresh status for all devices to verify that ETEMS can still communicate with all devices. If you 
cannot communicate with a device, it probably has an invalid or misconfigured certificate. 
Fix any issues discovered and proceed.
8 Enable strict authentication on all of the PEPs. 
9 Enable strict authentication on the ETKMSs. 
NOTE
If you need to add a new PEP after you have enabled strict authentication, temporarily disable strict 
authentication in the ETEMS preferences first, and then add the PEP. Configure the PEP as needed. After 
you push the configuration, install certificates on the PEP and re-enable strict authentication in ETEMS. 
Refresh status to test the communications and if everything is successful, enable strict authentication on 
the new PEP.
Related topics:
Certificate Information
When you generate a keypair and create certificates, you must provide information that uniquely 
identifies the device. This information is referred to as a distinguished name and consists of the values 
described in 
. When you generate a keypair using the keytool utility, this information is specified 
as part of the 
-dname
 parameter. 
Table 68
 Distinguished name information
Setting
Description
Common Name (CN)
A name that identifies the device or person. Length: 0-64 characters. 
Organizational Unit (OU)
Name of a sub-section of the organization, such as a department or 
division. Length: 0-64 characters.
Organization (O)
Organization or company name. Length: 0-64 characters. 
Locality (L)
City, town, or geographical area where the organizational unit is 
located. Length: 0-128 characters.
State/Province (S)
State or province where the organizational unit is located. Length: 0-
128 characters.
Country (C)
Two letter country abbreviation (optional).