Smeg SCB64MPX6 User Manual

Page of 20
Instructions for the Installer
61
14.INSTALLING THE APPLIANCE
The appliance must be installed by a qualified engineer in compliance with the relevant regulations. It
may be installed against walls one of which is higher than the worktop surface, as shown in the
installation class drawings A and B. Wall units or extractor hoods installed above the appliance's work-
top must be at least 75 cm above it.
A)  
 B)
14.1 Electrical connection
Check that the voltage and size of the power supply line are as specified on the nameplate inside the
storage compartment. This nameplate must never be removed.
If a permanent connection to the electrical mains is used, the appliance's power supply line must be
fitted with an omnipolar breaking device with contact breaking gap of at least 3 mm located in an easily
accessible position close to the appliance itself.
The mains connection may be permanent or by means of a plug and socket. If a plug and socket
connection is used, suitable cable compliant with the relevant standards must be used. For each type of
connection, the appliance must always be connected to earth. Before connecting it, check that the power
supply line is properly earthed. The use of adapters is not recommended since they may cause
overheating.
The appliance has a terminal board on its rear. Make the
electrical connection in accordance with the wiring diagram
shown below.
To access the terminal board, remove the guard on the rear.