Operation
VERIFYING THE OPERATION
Before beginning the test procedure, ensure that the gas supply is turned off at the
shut-off valve, all cooktop control valves are in the “OFF” position, and all burner
rings, burner caps, and grates are properly positioned on the cooktop.
Rotate one knob at a time counterclockwise to the “LITE/HI” position. Verify that all
ignitors spark continuously, then return the knob to the “OFF” position. Repeat for
all knobs. See Figure 8.
WARNING
WARNING
WARNING
WARNING
WARNING
If  the  cooktop  fails  to  operate  properly,  ensure  that  the  electrical  power  supply
and  gas  supply  are  turned  on  and  that  all  installation  steps  have  been  carefully
followed.  Call  a  qualified  service  technician  if  the  cooktop  still  does  not  operate
properly.
The  cooktop  and  shut-off  valve  must  be  disconnected  from  the  gas  supply  piping
during  any  pressure  testing  exceeding  1/2  pound  per  square  inch  (3.5  kPA).
The  cooktop  must  be  isolated  from  the  gas  supply  piping  by  closing  the  shut-off
valve  during  any  pressure  testing  at  or  below  1/2  pound  per  square  inch  (3.5  kPA).
Figure  8
Burner Control Valve