2. Attach terminal lugs to line 1 (black), bare (green) ground, and 
line 2 (red) wires. Loosen (do not remove) the set screw on the 
front of the terminal lug and insert exposed wire end through 
bottom of terminal lugs. Securely tighten set screw to torque 
as shown in the following Bare Wire Torque Specifications 
chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use 
³⁄₈" nut driver to connect the bare (green) ground wire to 
the center terminal block post with one of the 10–32 hex nuts.
4. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
Connect Range to Downdraft System
1. Attach flexible vent (provided) to the blower motor inlet using 
a vent clamp.
2. Check countertop height to allow range top to clear 
countertop. Adjusting leveling legs if necessary.
3. Remove access panel by grasping both sides, pulling 
upward, and lifting out.
4. Move range close to cabinet opening. 
5. Plug range into grounded outlet (if using a power supply 
cord).
6. Plug range electrical connector into the downdraft blower 
motor.
7. Remove cardboard or hardboard from under the range. Using 
2 or more people, gently move range into its final location.
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug
A
B
C
D
E
B
F
A
E
D
C
A. Inlet flexible vent
B. Vent clamp
A. Power supply cord (on some installations)
B. Range electrical connector to blower motor
1
2
1
A
B
A
B