PRODUCT MODEL NUMBERS
ELECTRICAL WIRING DIAGRAM
JGC8430CD
JGC8536BD
Gas supply: See page 1.
Electrical: This appliance is equipped with a grounded
type power cord. A grounded outlet must be provided. It
is recommended, for convenience, the outlet be located
within either the shaded area or the cross hatched area
shown at right. Or, if an electric wall oven is to be
installed below this appliance, locate the outlet within the
cross hatched area or within an adjacent cabinet.
User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCI) outlet or breaker is in use.
In planning any installation, note that the free length of
this appliance’s power cord is 46" (117 cm). The power
cord exits the bottom of the burner box from a point 
2-1/4" (5.7 cm) left of the right wall of the burner box,
and 1-9/16" (4 cm) forward of the rear wall of the burner
box, when viewed from the front of the unit.
30" (76.2 cm) and 36" (91.4 cm) Sealed Gas Cooktop
CABINET OPENING DIMENSIONS
4ʺ MAX.
10.16 cm
37 3/16 ʺ
94.46 cm
29 3/8ʺ
74.61 cm
3 13/16 ʺ
9.7 cm
CABINET BOTTOM
3 1/2ʺ (8.89 cm) WIDE
SLATS WHEN A WALL
OVEN IS INSTALLED
BELOW 30ʺ MODEL
Locate this appliance away from combustible materials such as
window curtains and combustible wall decorations.
Minimum horizontal clearance between the edge of the appliance
and combustible construction, extending from the cooking surface
to 18" (45.72 cm) above the cooking surface:
C = 3/4" (1.9 cm) at rear
D = 8" (20.3 cm) at sides
Dimensions apply to both 30" and 36" wide models.
A = 30" (76.2 cm) minimum vertical clearance between
cooking surface and construction above the
appliance. This clearance may be reduced to not
less than 24" (60.96 cm) by protecting the underside
of the combustible material or metal cabinet above
the cooking surface with not less than 1/4" (0.635
cm) insulating millboard covered with sheet metal
not less than 0.0122" (0.3 mm) thick.
B = 13" (33.02 cm) maximum depth of cabinets installed
above cooktop. 
Avoid use of cabinets above cooktop for storage space
to eliminate associated potential hazards such as
reaching over open flames.
3/4”
1.91 cm
18”
45.72 cm
8”
20.32 cm
A
B
C