Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing  
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
JENN-AIR
®
 DETAILED PLANNING DIMENSIONS
4 of 4
JRC120014A  07/2012  
DOwNDRAfT cOOkTOP DucTING ARRANGEMENTS
The diagrams below show typical duct arrangements for downdraft cooktops. JX3™ downdraft cooktops  
also offer a duct-free installation option. For more details, refer to page 3.
Roof jack
Transition elbow 
3
1
4
" x 10" 
(8.3 cm x 25.4 cm) duct – 
54' (16.5 m) max. 
REAR DuCTING THROuGH WALL TO OuTSIDE
REAR DuCTING IN WALL TO ROOF
DucTING cONfIGuRATIONS
CALCuLATING MAXIMuM DuCTING LENGTH
•  Maximum ducting length is 60' (18.3 m).
•  Each 90° elbow equals 5' (1.5 m) duct. 
•  Use no more than three 90° elbows. 
•  Flexible metal vent is not recommended.
• Do not install two elbows together.
NOTES:
•  For ducting runs up to 30' (9.1 m), install cooktop as shipped.
•  For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the  
restricter ring on the blower inlet housing.
•  For altitudes above 4500' (1272.0 m), reduce recommended  
vent run by 20% for best performance.
3
1
4
" x 10" 
(8.3 cm x 25.4 cm) duct
Transition elbow
6" (15.2 cm) 
diameter elbow
5" (12.7 cm ) to 6" (15.2 cm) 
diameter transition 
6" (15.2 cm) 
diameter wall cap
6" (15.2 cm) diameter duct – 
51
1
2
' (15.7 m) max. 
THROuGH FLOOR BETWEEN JOISTS TO OuTSIDE
SIDE DuCTING IN TOE KICK TO OuTSIDE
DucTING REQuIREMENTS
COOKTOp
DuCT LENGTH
DuCT SIzE
Gas
10' (3.0 m) or less*
5" (12.7 cm)  
diameter*
Between 10' (3.0 m) 
and 60' (18.3 m)
6" (15.2 cm)  
diameter
3
1
4
" x 10"  
(8.3 cm x 25.4 cm)
Electric
10' (3.0 m) or less**
5" (12.7 cm)  
diameter**
Between 10' (3.0 m) 
and 60' (18.3 m)
6" (15.2 cm)  
diameter
3
1
4
" x 10"  
(8.3 cm x 25.4 cm)
  *Gas cooktops must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.
** May be used to vent straight out the back of the cooktop and directly 
through the wall.