18. Set the control console back into place on the cooktop. For a 
proper fit, the flange of the control console must hook over 
the lip on the front of the cooktop.
19. Check that the control console is flush with the top edge of 
the cooktop.
20. Replace the 2 screws on each side of the control console.
21. Push the cooktop back into place in the cutout.
22. Replace the control knobs.
23. Replace burner grates. 
24. Plug in cooktop or reconnect power.
25. Test the flame by turning the control from LO to HI, checking 
the flame at each setting.
GAS CONVERSIONS
IMPORTANT: Gas conversions from Natural gas to LP gas must 
be done by a qualified installer.
LP Gas Conversion
1. Turn the manual shutoff valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the 
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “NAT” or “LP” position. Turn over the spring 
retainer so the “LP” is showing on the bottom. Snap the 
spring retainer back into the cap. Reinstall the cap onto the 
regulator.
A. Control console flange
B. Front lip of range cooktop
A
B
A. Flush with top of cooktop
A
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
A. Access cap
B. Gasket
C. Gas pressure regulator
D. LP position
E. NAT position
A
B
C
A
B
C
D
E