Cabinet Dimensions
NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the cooktop base. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.
A minimum side clearance of 6" (15.2 cm) is recommended 
between side of cooktop and side wall for maximum 
ventilation performance.
A minimum clearance of 
2" (5.1 cm) is recommended 
between the motor/blower and cabinet for proper cooling. A 
6" (15.2 cm) clearance is recommended for servicing access.
Cutout Dimensions
Venting Requirements
IMPORTANT: This cooktop must be exhausted outdoors unless 
using the Jenn-Air
®
 Duct Free Filter Accessory Kit. See “Venting 
Methods” section.
Do not terminate the vent system in an attic or other enclosed 
area.
Use a Jenn-Air
®
 vent cap.
Vent system must terminate to the outside.
Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is 
recommended. For best performance, do not use plastic or 
metal foil vent.
Before making cutouts, make sure there is proper clearance 
within the wall or floor for the exhaust vent.
Do not cut a joist or stud unless absolutely necessary. If a 
joist or stud must be cut, then a supporting frame must be 
constructed.
The size of the vent should be uniform.
The vent system must have a damper. If roof or wall cap has a 
damper, do not use damper supplied with the range hood.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the 
cap.
Determine which venting method is best for your application.
A. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform 
and bottom of uncovered wood or metal cabinet (24" [61 cm] 
minimum clearance if bottom of wood or metal cabinet is covered 
by not less than 
¹⁄₄
" [0.6 cm] flame retardant millboard covered with 
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 2" (5.1 cm)
F. 21
¹⁄₈
" (73.4 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of 
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of 
cabinet
J. 28
⁷⁄₈
" (73.4 cm) on 30" (76.2 cm) models
34½" (87.6 cm) on 36" (91.4 cm) models
K. 2½" (6.4 cm) minimum distance to nearest left and right side 
combustible surface above cooktop
L. 1½" (3.8 cm) minimum clearance between back wall and 
countertop
D
A
E
I
J
K
G
H
L
C
F
B
A. 28
⁷⁄₈
" (73.4 cm) maximum on 30" (76.2 cm) models
34½" (87.6 cm) maximum on 36" (91.4 cm) models
B. 21
¹⁄₈
" (53.7 cm) maximum on both 30" (76.2 cm) and 36" (91.4 cm) 
models
C. 8
⁵⁄₈
" (21.9 cm) on 30" (76.2 cm) models
15
⁷⁄₁₆
" (39.2 cm) on 36" (91.4 cm) models
D. 6
⁵⁄₁₆
" (16.0 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models
E. 2" (5.1 cm) minimum space to front edge of cooktop
F. Floor exhaust option
G. 6
¹⁄₈
" (15.6 cm) for 6" (15.2 cm) vent system
H. 8
⁵⁄₈
" (21.9 cm) on 30" (76.2 cm) models
15
⁷⁄₁₆
" (39.2 cm) on 36" (91.4 cm) models
I. 16" (40.6 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models