Jenn-Air W10298937B User Manual

Page of 24
3
45" (114.3 cm) Cooktop
 
*A minimum clearance of 
6¹⁄₄" (15.9 cm) is recommended for 
removal of the grease containers. Installed dimension for the 
grease containers is 5
¹⁄₂" (14.0 cm).
**A minimum clearance of 
2" (5.1 cm) is recommended between 
the motor/blower and cabinet for proper cooling.
Cabinet Dimensions
A. Tie down bolt (on each side of cookop)
B. 45" (114.3 cm)
C. 21
³⁄₄" (55.3 cm)
D. Grease containers
E. Wiring box cover
F. Blower
A. 6
¹⁄₄" (15.9 cm)
B. 3
¹⁄₂" (8.9 cm)
C. Grease containers
D. 2" (5.1 cm)
E. 13
³⁄₄" (34.9 cm)
F. 26
³⁄₄" (68.0 cm)
G. 4" (10.2 cm)
H. 13
¹¹⁄₁₆" (35.1 cm)
A
F
E
D
B
C
A*
D** 
C
B
E
F
G
H
C
A. 30" (76.2 cm) on 30" (76.2 cm) models
45" (114.3 cm) on 45" (114.3 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform 
and bottom of uncovered wood or metal cabinet (24" [61 cm] 
minimum clearance if bottom of wood or metal cabinet is covered 
by not less than 
¹⁄₄" [0.6 cm] flame retardant millboard covered with 
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 1
⁷⁄₈" (4.8 cm) min.
F. 21" (53.3 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of 
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of 
cabinet
J. 29
¹⁄₁₆" (73.9 cm) on 30" (76.2 cm) models
43
¹⁄₄" (109.9 cm) on 45" (114.3 cm) models
K. 2½" (6.4 cm) minimum distance to nearest left and right side 
combustible surface above cooktop
L. 1½" (3.8 cm) minimum clearance between back wall and 
countertop
D
A
E
I
J
K
G
H
L
C
F
B