STEP 1     CABINET OR WALL OPENING
CABINET OR WALL OPENING
Provide  an  opening  in  the  wall  or  cabinet  as  indicated  on 
fi gure 1. The depth should be a minimum of 24". The fl oor 
of  the  opening  should  be  constructed  of  plywood  strong 
enough to support the weight of the oven (about 100 lbs.) 
and should be level for proper operation of the oven.
Note:  While  the  proper  functioning  of  the  oven  does  not 
require that the opening be enclosed (with sides, ceiling and 
rear  partition),  this  may  be  required  by  local  code,  and  it 
is suggested that the local code be checked for any such 
requirement.
ELECTRICAL OUTLET LOCATION
This outlet should not be located in the shaded area of fi gure 
1. At the rear of the opening, provide a 3-pronged, polarized, 
electrical outlet, 115-120 volt A.C., 15 amp. or larger.
STEP 2     EXHAUST DUCT ASSEMBLY INSTALLATION
1. Insert the edge of DUCT-B into the hold lip of DUCT-C. 
Secure together by using a SCREW-A provided in the kit. 
Remove the existing screw #1 at upper right rear of the 
oven and secure DUCT-C with the screw #1 just removed 
from the oven. Secure DUCT-B with SCREW-A through 
the duct and into the original screw hole in the oven. See 
fi gure 2.
2. Secure  the  EXHAUST  DUCT  ASSEMBLY  with  two 
SCREWS A. See Figure 3.
3. Position DUCT-A2 on top of the oven and insert it into the 
hold lip of DUCT-A1. Secure DUCT-A2 to DUCT-A1 using 
two SCREWS-A provided. See fi gure 4.
4. Position  DUCT-A3  on  top  of  the  oven  and  insert  it  into 
DUCT-A2.  Secure  DUCT-A3  using  three  SCREWS-A 
provided.
DUCT-A1
SCREW-A
DUCT-B
SCREW-A
DUCT-C
DUCT-B
SCREW-A
SCREW-A
#1
20 
20 
11
//
88
""
25
25
11
//
44
"
18 
11
//
2
"
11 
11 
11
//
22
"
5"