Southbend STRE-3D User Manual

Page of 48
S
TRATO
S
TEAM 
C
OUNTERTOP 
S
TEAMER
 
S
ERVICE
 
O
WNER
M
ANUAL 
1185184 P
AGE 
23
 OF 
48 
 
 
 
Figure 12
    
Steamer Not Heating Up Properly or Not Cooking Properly, “Power” Light is Lit 
 
 
Steamer not heating properly or not cooking properly,  
“Power” light is lit. 
Check resistance between heating-cartridge contactor terminals 
and replace heating cartridges as necessary (see page 25). 
Replace door switch. 
Reconnect door switch lead wires. 
Door switch OK? 
No 
Yes
Check door switch (see page 29). 
Check water-level control sensor (see page 31). 
Water-level control 
sensor OK? 
No
Yes
Replace water-level 
control sensor. 
DISCONNECT POWER AT CIRCUIT BREAKER 
Is water level at 
normal level in cavity? 
No 
Yes
Turn off steamer and check that it drains completely. If steamer 
does not drain, check drain path for obstructions. Turn steamer 
back on and wait 10 minutes.
High-limit thermostats OK? 
No
Yes
Replace high-limit 
thermostats as necessary.
DISCONNECT POWER AT CIRCUIT BREAKER 
Check that water-supply pressure is adequate. 
Check high-limit thermostats (see page 30). 
Replace water solenoid. 
Water solenoid OK? 
No 
Yes
Check water solenoid (see page 32). 
Check for loose or broken 
wires (see wiring diagram). 
If wiring is OK, remove screen 
from strainer and clean or 
replace as necessary. 
Reassemble, reconnect, and 
recheck the steamer. If water 
still does not enter the 
steamer, examine the water 
solenoid and inline Y strainer 
for obstructions or deposits. 
Clean or replace as 
necessary. 
Check contactor (see page 27). 
Replace contactor. 
Contactor OK? 
No
Yes
Check for loose or broken 
wires (see wiring diagram). 
If wiring is OK, check that 
heating cartridges are secure 
(tighten to 75 inch-pounds of 
torque).