Contact your local syrup or beverage equipment distributor for additional information and troubleshooting 
of beverage system.
Observations of LED Lighting on Customer Interface Keypad
Symptom
Cause
Remedy
1
Bonus Flavor Icon and/
or Drink Icon LEDs (see 
FIGURE 4) are ON 
continuously with four 
quick flashes every 30 
seconds.
A. This indicates a poor 
connection in the lighting 
synchronization harness 
that connects the interface 
boards together.
A. Turn the keyswitch to disconnect 
power to the interface boards. Check the 
electrical connections between the 
harnesses that interconnect the right 
side of all interface boards together. Turn 
back the keyswitch to reconnect power.
2
Bonus Flavor Icon and/
or Drink Icon LEDs (see 
FIGURE 4) are not in 
sync with the lighting 
sequence, 
B. This may result over time 
as the lighting sequence 
between push button pads 
can become slightly out of 
synchronization.
B. Unplugging the unit and performing a 
power up will re-synchronize the lighting 
sequence.
3
Keypad LED lighting is 
not working
A. Poor connection between 
interface board and keypad 
PCB
A. Turn the keyswitch to disconnect 
power at the interface boards. Check 
harness connections at each interface 
board.
B. Keypad LED's are burnt 
out
B. Turn the keyswitch to disconnect 
power at the interface boards. Unplug 
the ribbon cable from one interface 
board and test it by plugging it into the 
neighboring interface board.   If the 
keypad still doesn't light up replace the 
keypad PCB.
C. Interface board is 
defective.
C. Turn the keyswitch to disconnect 
power at the interface boards. Unplug 
the ribbon cable from one interface 
board and test it by plugging it into the 
neighboring interface board. If the LED's 
light up the interface board is defective. 
Replace the interface board.
D. Corrosion at connector 
between keypad and ribbon 
cable.
D. Replace keypad circuit board and 
ribbon cable.
E. Main control board is 
defective.
E. Replace the main control board.
4
During standby mode, 
the brand and bonus 
LED icons do not 
alternate back and forth 
- instead they light 
together.
Bonus buttons are 
incorrectly programmed as 
brand buttons, or vice versa.
Check the programming of each keypad 
and set each button as CW, PW, or 
timed dispense based upon the flavor 
lineup.