Installation and Tapping – 
Direct Draw Dispensers Self-Contained
Connecting the Regulator to the 
CO
2
Cylinder
Remove blue plug from regulator fitting. 
(Note: Do not remove the carbonic washer).
Screw regulator onto gas cylinder valve. Tighten
with wrench until vertically straight. Be sure that 
shut-off valve (black lever) on regulator is in 
the OFF (horizontal) position.
Place a screw clamp over end of red air line 
and push onto regulator tailpiece. Tighten clamp
with a screwdriver.
Adjusting the CO
2
Gas Flow 
Turn regulator adjusting screw counterclockwise
until it turns freely.
Turn hand valve counterclockwise on CO
2
cylinder to the fully open position.
Turn regulator adjusting screw clockwise until 
desired pressure is reached (approximately 
12-15 lbs.). Tighten stop nut on adjusting screw.
Open shut-off valve on bottom of regulator.
CO
2
Leak Test
Dilute a small amount of liquid dishwashing soap
and rub the soapy mixture around each connection.
If bubbles appear, tighten connection.
Replacing CO
2
Gas Cylinder
Turn CO
2
hand valve clockwise until seated and
close shut-off valve on regulator.
Unscrew regulator from cylinder fitting.
Replace carbonic washer (Part No. 157F2P), 
if needed and reattach regulator to filled 
cylinder.
Turn CO
2
hand valve counterclockwise until 
fully open. Turn regulator shut-off valve to 
open position.
Adjust CO
2
gas flow as required, turning
clockwise for higher pressure.
Proper CO
2
Handling
ALWAYS
...
Connect a regulator (reducing valve) to 
CO
2
cylinder.
Secure cylinder in upright position whether in 
storage or in use.
Keep cylinder away from heat. Rupture disc 
vents at 122° F. maximum.
Ventilate room after high pressure gas leakage.
Check the last DOT test date on cylinder neck 
before filling. If more than five years old, the 
cylinder must be retested to DOT specifications.
Be sure CO
2
cylinder outlet fitting is free of dust 
or dirt before attaching regulator.
Store CO
2
cylinder and regulator assembly 
upright.
Allow only properly trained and experienced 
personnel to handle high pressure gas. 
NEVER
...
Connect cylinder directly to a keg without a 
regulator (reducing valve).
Drop or throw regulator or CO
2
cylinder.
Transport CO
cylinder in a closed vehicle.
Apply oil to a regulator. 
Shut off CO
cylinder when not in use. You will 
not save gas by doing so!
Allow untrained, inexperienced personnel to 
handle high pressure gas.
Failure to heed this warning could result in 
personal injury or death.