Viking 200 User Manual

Page of 12
UL approved
strain relief
d
Common
Green
Ground
White
Black
Run wires through bottom pan. Using a UL approved
strain relief, connect wires to terminal block.
e
Green
Ground
Connect ground wire.
NOTE: Reinstall front plate and bottom pan.
12
13
Hardwire Conduit Option
a
1
b
Remove any loose items in the dishwasher and carefully lay
the dishwasher on its back. NOTE: Be careful not to pinch
hoses or power cord beneath dishwasher.
Remove bottom pan and front plate. Rapid removal
of the bottom pan will cause damage to the moisture
sensor. To remove the bottom pan for installation and
servicing, slowly pull the bottom pan from the unit
and disconnect the connector wire from the moisture
sensor which is located on the floor of the bottom
pan.
c
Loosen ground wire and wires on terminal block.
Loosen strain relief and remove cord.
NOTE: Other items are grounded in this location–these
items must remain grounded.
Trim Installation Options 
(not available on all units)
1a
To install dishwasher without trim, remove the 6 screws (3 per side) and
remove trim. To attach wiper gasket to dishwasher, pull protective film off
adhesive back on wiper gaskets and apply to leading edge of dishwasher
frame. Trim gasket to fit.
1b