The  primary  air  intake  regulator  (2)  is  set  with  the 
reference notch showing “GPL” corresponding te the 
secuting screw (3).
The flame is regulated (minimum and maximum) to 
suit this type of gas.
If  the  machine  is  to  be  used  with  a  different  type 
of  gas,  it  will  be  necessary  to  replace  the  injector 
in  accordance  with  the  above  table  and  to  rotate 
the  primary  air  regulator  (2),  which,  in  the  case  of 
natural  gas,  will  have  to  be  set  with  the  reference 
notch  showing  “N”  corresponding  to  the  securing 
screw (3).
To do this, it will of course be necessary to loosen 
the securing screw (3) and to tighten it again after 
rotating the primary air intake regulator (2).
Connections to mains gas, from the gas tap available 
in the room to the valve fitted on the machine, must 
be carried out in accordance with the regulations in 
force, using a flexible pipe or a rigid pipe in annealed 
copper.
In  the  latter  case,  the  special  rubber-pipe  fitting  in 
connected tightly to the valve by means of the bico-
nical nozzle and securing nut supplied.
The flexible pipe is fitted over the end of the mains 
outlet and secured with the metal strip supplied.
Alternatively, the annealed copper pipe can be con-
nected up, again using the special biconical nozzle 
and the appropriate nuts, directly to the valve.
Once  the  machine  has  been  connected  up  to  the 
gas main, and after filling the boiler up with water in 
accordance with the instructions in the booklet (“IN-
STRUCTIONS  FOR  USE  AND  MAINTENANCE”), 
the burner can be lit in the following manner:
 
Open the main gas tap.
 
Press on the gas valve knob, on the machine rotate 
it  90°  anti-clockwise,  and  keep  it  pressed  in.  At 
the same time, press the piezoelectric lighter one 
or more times – the lighter knob bears a symbol 
resembling a spark – until the burner lights up.
 
Wair  about  20  seconds,  then  release  the  valve 
knob and the burner should stay lit – the flame is 
vidible through the special hole in the panel behind 
the dispenser units.
N.B.
Should  the  burner  not  light  up,  do  not  persist,  but 
release the valve knob, and then check that lighter 
spark  on  the  burner  is  in  order  and  about  5  mm 
long.
Should the flame go out when te valve knob is re-
leased, check the position of thermocouple and the 
circuit connected to it.
The flame should be bright blue; if not, slightly regu-
late the primary air intake (2) until the desired effect 
is achieved.
Wait  until  the  machine  has  the  correct  pressure, 
according to instructions. Otherwise, adjust the gas 
pressure regulator, which has two regulating screws. 
The one that protrudes more (4) serves to regulate 
the  boiler’s  operating  pressure,  while  the  other  (5) 
serves to set the flame at the minimum.
When  the  machine  is  pressurized,  check  to  see 
that the minimum flame is correct by adjusting the 
screw (4) if necessary; after loosening the locking-
nut, unscrew the screw until it feels loose (the main 
gas-pipe is closed), and check whether, under these 
conditions, the low flame remains lit, thus acting as 
a pilot.
If the flame is too high, it will be necessary to regulate 
screw (5), turning it slightly clockwise, of course after 
having loosened the locking-nut. If, on the contrary, 
the flame tends to go out, then regulate screw (5) by 
turning it anti-clockwise, until a very low, but constant 
flame is obtained. Having achieved this correct adju-
stment of the minimum flame, hold the screw still and 
lock it with the locking-nut.
Then rotate the screw (4) clockwise until there is a 
there is a high flame, and wait for the boiler to reach 
the  desired  operating  pressure:  if  the  flame  dies 
down before reaching the required pressure, tighten 
screw (4) further; if the flame dies down at a higher 
pressure, then unscrew the screw.
Check  once  or  twice  by  opening  the  steam  tap  to 
release the pressure in the boiler, then hold screw 
(4) still and lock it with the locking-nut.
13. MACHINES WITH ALTERNATIVE GAS 
HEATER VERSION 
(Fig.14)
N.B.  Installation  of  the  machine  and  any 
adjustment or adaptation to the type of gas 
should  be  done  by  a  technically  qualified 
person.
The machine leaves the factory all set for use with 
liquid gas (GPL).
The gas regulator (1) is therefore fitted with the ap-
propriate injector shown in the table below:
Model
Nominal
thermic
capacity
GPL
G30 - 29 mbar
(cent of milimeter)
Natural gas 
G20 - 20 mbar
(cent of milimeter)
2 Gr. 
2,5 KW
(2150 Kcal/h.)
75
102
3-4 Gr
3,3 KW
(2850 Kcal/h.)
90
135