TECHNICAL CHARACTERISTICS  
 
 
 
 
Dimensions:   Height 66.5 cm 
 
 
Width 35 cm 
 
 
Depth 41 cm 
 
Weight: 
25 Kg 
 
 
Voltage supply: 230 Vac. 50 Hz or 120 Vac. 60Hz on request  
 
Absorbed power: 1,6 KW  
 
Selections: 8 selections.  
 
System of payment: predisposed for  
 
 12V Parallel coin mechanism 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Pag. 23 
TROUBLESHOOTING GUIDE 
The machine is provided with a program of self-diagnosis, that allows to visualize 
on the display the messages of breakdown or machine stopped :  
 
 
ERROR GROUP 1 
the coffee-group has not reached the “supply position” given by its right 
micro switch. Check Fuses, group right micro switch, group motor, 
electronic board.. 
 
ERROR GROUP 0 
the coffee-group has not reached the “normal  position” given by its left 
micro switch. Check Fuses, group left micro switch, group motor, elec-
tronic board. 
 
ERR. COFFEE FLOW 
During espresso supplying, the board has not received signals from the 
flowmeter. Check fuses, too fine coffee, coffee pump, coffee electro 
valve, flowmeter, electronic board. 
 
 
ERROR GRINDER  
During the coffee grinding, the board has not received the signal given 
by the doser-switch in the maximum time of 25 seconds. Check  too 
fine coffee, fuses, doser micro-switch, grinder motor, grinder blocked 
by something hard, electronic board. 
 
LACK OF WATER 
The board doesn’t receive the signal from the float. Lack of water, float, 
water container micro switch, electronic board. 
 
ERROR BOILER  
The board has not received the programmed value temperature from the 
boiler probe in the maximum time of 15 minutes. Check safety thermo-
stat, boiler heating element, electronic board. 
 
EMPTY GROUNDS! 
The coffee grounds decounter has reached the programmed value. 
Empty the grounds and execute the quick function nr.5. 
 
ERROR EXECUTIVE 
The board does not receive signals by the payment system, Executive or 
MDB, programmed. Check payment system, cables, electronic board.. 
 
 
All the alarms are deleted, once the trouble is solved, switching off the machine.