DeLonghi ICM15240 User Manual

Page of 8
7
use
en
Technical data
Mains voltage:
220-240V˜50/60Hz
Absorbed power:
1000W
Weight: ICM15240 / ICM15250
2.3 kg
Disposing of the appliance
In  compliance  with  European  directive  2002/96/EC,
the appliance must not be disposed of with household
waste,  but  taken  to  an  authorised  waste  separation
and recycling centre.
   
The appliance complies with the following EC direc-
tives:
•  Low  Voltage  Directive  2006/95/EC  and  subsequent
amendments;
•  EMC Directive 2004/108/EC and subsequent amendments
•  EC Regulation 1275/2008 for standby.
Troubleshooting
Problem
Probable cause
Solution
The  coffee  takes  longer  to
brew.
The coffee maker needs to be descaled.
Descale the machine as described in the section
DESCALING.
The coffee has an acidic
taste.
Insufficient rinsing after descaling.
Rinse the machine as described in the section
DESCALING.
Electrical connection (UK only) 
A)  If your appliance comes fitted with a plug, it will incorporate a 13 Amp fuse. If it does not fit your socket, the plug should be cut
off from the mains lead, and an appropriate plug fitted, as below.
 
WARNING: Very carefully dispose of the cut off plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house
as this could cause a shock hazard. With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse.
If the plug is a moulded-on type, the fuse cover must be re-fitted when changing the fuse using a 13 Amp Asta approved fuse to
BS 1362. In the event of losing the fuse cover, the plug must NOT be used until a replacement fuse cover can be obtained from your
nearest electrical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug.
B)  If your appliance is not fitted with a plug, please follow the instructins provided below:
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPoRTANT
The wires in the mains lead are coloured in accordance with the following code:
Green and yellow:
Earth
Blue:
Neutral
Brown:
Live
As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug,
proceed as follows: The green and yellow wire must be connected to the terminal in the plug marked with the letter E or the earth
symbol 
or coloured green or green and yellow. The blue wire must be connected to the terminal marked with the letter N or
coloured black. The brown wire must be connected to the terminal marked with the letter L or coloured red.
A