Stanley Black & Decker GT18B02 User Manual

Page of 27
12 ► GT18B01-B02 User Manual
OPERATION
CONTROLS
This unit is equipped with an advanced proportional engine 
control system. It provides a means of controlling engine 
speed by adjusting the fuel control lever with an actuator. 
The Power Unit provides one circuit, with an oil flow of 5 
gpm/19 lpm up to 2000 psi/140 bar or 8 gpm/30 lpm up 
to 2000 psi/140 bar with a factory-programmed electronic 
governed engine throttle.
Figure 3. Control Panel
One hydraulic tool can be connected to the tool circuit. 
The circuit is activated by turning the flow control switch to 
either the 5 gpm/19 lpm or 8 gpm/30 lpm setting.
THROTTLE CONTROL
The throttle control permits the operator to select one of 2 
operating modes after the engine has warmed up. When 
starting the engine, make sure the flow selector switch is 
in the off position. The throttle control switch can be set in 
either the auto-idle-on or auto-idle-off positions.
AUTO-ON
When the throttle control switch is in the "AUTO-ON" posi-
tion, the oil flow is regulated automatically when the trigger 
on the tool is activated. When the tool is not being used the 
engine will return to idle automatically, after a 10 second 
delay.
 
This setting will produce 5 gpm/19 lpm or 8 gpm/30 lpm 
depending on which postion the operator has selected with 
the flow selector switch.
AUTO-OFF
When the throttle control switch is in the "AUTO-OFF" posi-
tion, the engine speed is held to maintain 5 gpm/19 lpm or 
8 gpm/30 lpm depending on which position the operator 
has selected with the flow selector switch. When a tool is 
not being used the engine will not return to idle until either 
the flow selector switch is turned to the off position or the 
throttle control switch is turned to auto-on.
Note:
It may be necessary to reset the Controller. 
At times it may be neccessary to reset the controller. This 
could happen if a fault occurs in the controller. For ex-
ample, excessive engine speed. If a fault does occur the 
power unit will return to an idle and the operator will have 
no control of the unit. To reset the controller, simply turn off 
the power unit and restart it.
STARTUP
Before starting the engine make sure the flow selector 
switch is in the OFF position. 
Note: 
The power unit will not start if the flow control switch is 
not in the "OFF" position. 
Pull choke knob out and move the Throttle Control Switch 
to the auto-idle-off or the auto-idle-on position, whichever 
mode of operation the operator prefers. Ensure the flow 
selector switch is in the OFF position.
Turn the Ignition Switch to the START position. After the 
engine starts, release the switch.
Gradually push in the choke knob as the engine begins to 
idle smoothly.
Allow the engine to warm up.
Connect hoses and the tool as desrcribed in this manual.
FOR 5 GPM OPERATION
For 5 gpm operation, select mode of operation with the 
Throttle Control switch, either auto-idle-on or the auto-idle-
off position. Move the flow selector switch to the 5 gpm 
position.
When finished operating the tool, move the flow selector 
switch to the OFF position.
FOR 8 GPM OPERATION
For 8 gpm operation, select mode of operation with the 
Throttle Control Switch, either auto-idle-on or the auto-idle-
off position. Move the flow selector switch to the 8 gpm 
position.
When finished operating the tool, move the flow selector 
switch to the OFF position.
throttle
 
control
 
switch
flow
 
selector
 
switch
ignition
 
switch