Panasonic AW-PH405N User Manual

Page of 32
4
Connections
 Turn off the power of all the equipment before proceeding with the connections.
 Connect the AC power cable supplied with the AW-PH405 for the AW-PH405 indoor pan-tilt head.
  Use 10BASE-T straight cables to connect the RP connectors on the pan-tilt heads with the CONTROL OUT TO PAN/TILT 
HEAD (1 to 5) connectors on the AW-RP655 multi-function controller and AW-RP555 multi hybrid control panel. The maximum 
extension distance is 81 ft (1000 meters) when using UTP category 5 cables or their equivalent.
 Use the camera cables supplied with the pan-tilt head to connect the AW-PH405 to the convertible camera.
  Connect the iris control cable of the motorized zoom lens to the IRIS connector on the camera, and connect the zoom/focus 
cable to the LENS I/F (1) connector on the pan-tilt head.
Motorized zoom lens
Iris control cable
Convertible camera
Monitor
Camera cable 
supplied with 
AW-PH405
Zoom/focus 
control cable
AW-PH405 
Indoor Pan-tilt Head
Pan-tilt head/camera control signals
AW-RP655 
Multi-function controller
AW-PS505A 
AC adapter
AW-RP555 
Multi Hybrid Control Panel
AW-PS505A 
AC adapter
10BASE-T 
straight cable
BNC cable video signal
For a convertible camera
AC power cable 
supplied with 
AW-PH405
To the 
LENS I/F (1) 
connector
AW-PS505A 
AC adapter
AW-PS505A 
AC adapter
AW-CB400 
Remote operation 
panel
AW-IF400 
Protocol converter
AW-RP400 
Pan-tilt control panel
•  AW-IF400 
Switch settings
SW1 SW
SET UP
1
4
ON
ON
OFF
OFF
OFF
OFF