Lincoln 1000 User Manual

Page of 20
Impinger I – 1000 Series Ops Manual 
IMPINGER
®
 I AND III CONVEYOR OVENS – MODEL SERIES 1000 AND 1200 
 
 
UTILITY SPECIFICATIONS REQUIRED – ELECTRIC 
 
Model 
Energy 
Power 
Voltage 
Current 
Phase 
Hz 
Recommended Electrical 
Specifications 
Agency 
Listing 
***1021-xxx-E 
Electric 
27 kW 
400/230 VAC 
40 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
F-G 
1022 
Electric 
27 kW 
120/208 VAC 
80 Amps 
60 Hz 
5 Wires, 3 Poles 
1N-1G 
A-B-F 
1023 
Electric 
27 kW 
120/240 VAC 
70 Amps 
60 Hz 
5 Wires, 3 Poles 
1N-1G 
A-B-F 
1028 
Electric 
27 kW 
380Y/220 
VAC 
41 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
1029 
Electric 
27 kW 
415/240 VAC 
38 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
1032 
Electric 
27 kW 
380Y/220 
VAC 
41 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
1202 
Electric 
27 kW 
120/208 VAC 
80 Amps 
60 Hz 
5 Wires, 3 Poles 
1N-1G 
A-B-F 
1203 
Electric 
27 kW 
120/240 VAC 
70 Amps 
60 Hz 
5 Wires, 3 Poles 
1N-1G 
A-B-F 
1228 
Electric 
27 kW 
380Y/220 
VAC 
41 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
1229 
Electric 
27 kW 
415/240 VAC 
38 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
 
 
UTILITY SPECIFICATIONS REQUIRED – GAS 
 
Model 
Energy 
Power 
Voltage 
Current 
Phase 
Frequency 
Recommended 
Electrical 
Specification 
Gas 
Agency 
Listing 
1030 
Nat. Gas 
35 kW 
220 
VAC 
1.6 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
35 kW/hr at 17.5 
mB H
2
O column 
1031 
L.P. Gas 
35 kW 
220 
VAC 
1.6 Amps 
50 Hz 
3 Wires, 1 Pole 
1N–1G 
35 kW/hr at 27.5 
mB H
2
O column 
***1033-xxx-E 
Nat. Gas 
35 kW 
230 
VAC 
3 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
35 kW/hr at 17.5 
mB H
2
O column 
F-G  
***1034-xxx-E 
L.P. Gas 
35 kW 
230 
VAC 
3 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
35 kW/hr at 27.5 
mB H
2
O column 
F-G  
1040 
Nat. Gas 
120,000 
BTU 
120/230 
VAC 
5 Amps 
60 Hz 
4 Wires, 1 Pole 
1N-1G 
120,000 BTU at 7 
inches H
2
O column 
A-F 
1041 
L.P. Gas 
120,000 
BTU 
120/230 
VAC 
5 Amps 
60 Hz 
4 Wires, 1 Pole 
1N-1G 
120,000 BTU at 11 
inches H
2
O column 
A-F 
1042 
Nat. Gas 
120,000 
BTU 
230 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 7 
inches H
2
O column 
1043 
L.P. Gas 
120,000 
BTU 
230 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 11 
inches H
2
O column 
1046 
Nat. Gas 
126 MJ 
240 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
126 MJ/hr at 1.75 
kPa H
2
O column 
E-F 
1047 
L.P. Gas 
126 MJ 
240 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
126 MJ/hr at 1.75 
kPa H
2
O column 
E-F 
1240 
Nat. Gas 
120,000 
BTU 
120/230 
VAC 
5 Amps 
60 Hz 
4 Wires, 1 Pole 
1N-1G 
120,000 BTU at 7 
inches H
2
O column 
A-F 
1241 
L.P. Gas 
120,000 
BTU 
120/230 
VAC 
5 Amps 
60 Hz 
4 Wires, 1 Pole 
1N-1G 
120,000 BTU at 11 
inches H
2
O column 
A-F 
1242 
Nat. Gas 
120,000 
BTU 
230 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 7 
inches H
2
O column 
1243 
L.P. Gas 
120,000 
BTU 
230 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 11 
inches H
2
O column 
 
 
NOTE: All ovens require separate service and dedicated neutral.