Connections
 Precautions when controlling the 
AK-HC1500 from the AW-CB400
The AK-HC1500 supports the AK-HRP150 protocol and 
AW-CB400 protocol, and it is the AK-HRP150 protocol 
which was set before the AK-HC1500 was shipped from the 
factory.
When controlling the AK-HC1500 using the AW-CB400, 
follow the steps below to change the protocol setting of 
AK-HC1500 from AK-HRP150 to AW-CB400.
  When changing the protocol before installation
Refer to the operating instructions of the AK-HC1500, 
and change the protocol.
  When changing the protocol after installation
  Proceed with the installation following the steps given 
in the section entitled “Installation”.
  Loosen the two top cover open/close bolts of the 
camera housing, and open the top cover.
 Set the power switch of the AC adapter to ON.
  When the power of the AK-HC1500 has been 
turned on, refer to the operating instructions of the 
AK-HC1500, and change the protocol. (Change the 
PROTOCOL setting on the SETTING menu to “4.”)
 Set the power switch of the AC adapter to OFF.
Connections with AC adapter
   Disconnect the AC power cable which was already 
attached.
   The cable used is purchased locally. Purchase a water-
proof cable designed to be used outdoors. 
   Use a cable which has a high enough capacity (AC 120 V 
2 A or more).
   Pass the cable through the rubber bushing for the AC 
power input cable, and tighten it securely so that rain 
water or drops of water will not seep inside. 
[Thickness of compatible cable: 1/4” to 5/16” (6.5 to 8.5 mm) 
diameter]
  Attach the power line (N, L) to the terminal block. 
  Attach the ground line (FG) to the grounding screw (
).
AC IN
DC15 V 
OUT
AC power 
input cable
Rubber bushing
FG 
L