INSTALLATION 
 
 
 8                                                                  L20-331, rev.02 (08/11) 
CAUTION 
Connecting the appliance to the wrong power supply may damage the appliance and void 
the warranty. 
 
WARNING 
DO NOT attempt to connect the appliance to an electrical supply other then that indicated 
on the data plate. 
WARNING 
The electrical connection used by this appliance must comply with local codes. If there are 
no local codes that apply, refer to the National Electrical Code (NEC), ANSI/NFPA 70 for 
installation in the US.  In Canada, refer to CSA Standard C22.2 and local codes.  In all other 
cases, refer to local and national codes and regulations. 
WARNING 
This equipment must be installed so that the plug is accessible unless other means for 
disconnection from the power supply (e.g. a circuit breaker) is provided. 
North America
International
Input Voltage
120 VAC, 50/60 Hz
220,230 or 240 VAC, 50/60 Hz
Current/Unit
1.0 Amp(s)
0.5 Amp(s)
Electrical Requirements
 
WARNING 
If your appliance uses line current, it is equipped with an oil proof, electrical supply cord with a 
three-prong safety plug. This is to protect operators from electrical shock hazard in the event 
of an equipment malfunction. DO NOT cut or remove the grounding (third) prong from this 
plug; it should be plugged into a properly grounded three-prong receptacle. 
1.6.   ELECTRICAL CONNECTIONS 
It is advised that this appliance be plugged into a wall receptacle that is controlled by the ventilation control. This will 
prevent the appliance from being operated without the ventilator on. If your appliance requires an electrical 
connection, the power requirements are listed below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.7.  VENTILATION AND FIRE SAFETY SYSTEMS 
Your new appliance must have proper ventilation to function safely and properly. Exhaust gas temperatures can reach 
as high as 750 °F (398 °C). Therefore, it is very important to install a fire safety system. Your ventilation system 
should be designed to allow for easy cleaning. Frequent cleaning and proper maintenance of the ventilation system 
and the appliance will reduce the chances of fire. Ventilation and fire safety systems must comply to local and national 
codes. In North America refer to ANSI Z83.11-CSA 1.8 for a list of reference documents that will provide guidance on 
ventilation and fire safety systems.  For installations in U.S. and Canada, additional information can be obtained from 
CSA International, 8501 East Pleasant Valley Road, Cleveland, OH, 44131 or visit their website at www.csa-
international.org.
 
 
It is essential that the appliance be operated only when adequate ventilation is provided. Your ventilation hood should 
be properly maintained. A qualified installation professional should ensure that the hood is operating properly in 
conjunction with the appliance. Inadequate ventilation may not properly evacuate appliance all emissions. Excessive 
or unbalanced ventilation may cause drafts, which could interfere with proper operation of the pilot and burners. Leave 
at least 18 inches (45.72cm) of open space between the flue of the appliance and the intake of the exhaust hood.