ADIC 601354 User Manual

Page of 196
Administrative Tasks
601354 Rev A
Getting Started
1-19
Gett
ing Star
te
d
Archive 
Dispatcher
The following table lists the variables that can be modified, as 
required, to modify archive communication times. VolServ 
must be cycled for the changes to become effective.
LIB_IPC_WAIT_TIME
5
Number of seconds this process pauses 
between attempts to send information over 
IPC. Increase this parameter if IPC traffic is 
extremely heavy.
LIB_IPC_RETRIES
30
Maximum number of times this process 
attempts to send information over IPC. 
Increase if IPC traffic is extremely heavy.
Library Manager Variables
LIBMAN_INTERFACE_TIME
60
Number of seconds this process waits to 
receive expected status over IPC. Increase 
if IPC traffic is extremely heavy.
LIBMAN_IPC_WAIT_TIME
5
Number of seconds this process pauses 
between attempts to send information over 
IPC. Increase this parameter if IPC traffic is 
extremely heavy.
LIBMAN_IPC_RETRIES
30
Maximum number of times this process 
attempts to send information over IPC. 
Increase if IPC traffic is extremely heavy.
Library Scheduler 
Variable Name
Default
Description
Variable Name
Default
Description
ARCDISP_IPC_RETRIES
10
The number of retries that the archive 
dispatcher tries to connect to the VolServ 
process before failing.