MAINTENANCE
WARNING: HOT FRYING COMPOUND AND PARTS CAN CAUSE BURNS. USE CARE WHEN
OPERATING, CLEANING OR SERVICING THE FRYER. USE CARE WHEN FILTERING.
WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE
THE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW  LOCKOUT/
TAGOUT PROCEDURES.
Fig. 18
Fig. 19
PL-41621
PL-41622
Fig. 17
PL-41619
PL-41620
Fig. 16
CLEANING THE FILTER DRAWER
1. Pull the filter drawer out and remove the filter tank cover.
2. After filter parts have cooled, lift the filter tank out of the
drawer (Fig. 16). Set the filter tank aside.
3. Lift the drawer from the drawer slides (Fig. 17) and set
the drawer aside.
4. Lift the drawer slides up and off the slide guides (Fig.  18).
5. Carry the parts to the sink area for cleaning.
6. Remove the crumb basket from the filter tank.
7. Remove and disassemble the filter screen assembly for
cleaning (Fig. 19). The top left side of the assembly has
a metal latch and bar.  Slide the metal latch off the bar. Lift
the bar up to allow access to the internal filter.
NOTE: The filter screen assembly should be cleaned daily. The
filter screen assembly parts may be placed in a dishwasher or
cleaned using a sink spraydown hose with dish detergent.
However, periodic fryer boil-out cleaning is recommended to
remove thick grease residue on the filter screen assembly. This
residue may hinder the filtration process. If you notice that the oil
filter return time is taking longer than 4 minutes to complete the
filter cycle, boil-out of the screen assembly is recommended.
This can be performed as part of the normal fry tank boil-out
procedure (see Fryer Boil-Out Instructions on page 11).
8. Wash all parts of the filter, including the drawer and
drawer guides, in normal dishwashing detergent. All
parts are dishwasher-safe and can be cleaned in a
commercial dishwasher instead of by hand.
9. Rinse parts thoroughly and wipe dry with a clean cloth.
All parts must be completely dried before reuse.
10. Reinstall all removed filter parts before operating the
filter system.
11. The top cover must be replaced before operating this
system.