Vulcan-Hart GRD65F ML-126738 User Manual

Page of 12
– 3 –
OPERATION AND CARE OF
KLEENSCREEN FILTRATION SYSTEM
SAVE THESE INSTRUCTIONS
GENERAL
The KleenScreen Filtration System filters the oil as it is pumped back to its respective tank. Valves
inside the doors under each fry tank must be set so only one tank is being drained, filtered and pumped
back at any one time.
The KleenScreen Filtration System is used on the following Vulcan Fryer Models:
Gas Fryers
Electric Fryers
GR35F
GRD35F
GRC35F
ERD50F
ERC50F
GR45F
GRD45F
GRC45F
ERD85F
ERC85F
GR65F
GRD65F
GRC65F
GR85F
GRD85F
GRC85F
ASSEMBLY
1. After unpacking, wash the filter tank, crumb basket and filter screen. Use dishwashing detergent
and warm water, or clean the components in a dishwasher.  Rinse the filter tank, crumb basket
and filter screen thoroughly.  Wipe components dry with a clean cloth.
2. Pull the filter drawer out.
3. Place the filter tank in the filter drawer. Hang the crumb basket from the left tank handle inside
the filter tank (Figs. 1 and 2).  Position the filter screen assembly flat on the bottom of the filter
tank so the filter orifice underneath the screen fits the suction hole in the bottom of the tank (Figs.
1 and 2).  Close the drawer.
4. Make sure the two O-Rings are in place inside the filter suction port (Figs. 1 and 2). As the drawer
is closed, make sure the filter suction connector fits tightly into the filter suction port (Figs. 1 and 2).