4. Freezers – Energy Saving Operating Mode 
a) Sequence of Operation
Note:  
 
1) Cut-on, cut-off, and cabinet temperature are read by the same sensor, called the "cabinet 
 
        thermistor." 
 
) The defrost thermistor reads the evaporator temperature.
Five minutes after 
defrost heater off
1. Compressor on
. Condenser fan on
Five minutes after 
compressor start-up
1. Evaporator fan(s) on
Eight minutes after evaporator 
fan start-up "dF" no longer 
displayed, cabinet temperature 
displayed
Board Self Check
1. Frame heater(s) on
. Evaporator fan(s)
    cycles on and off
POWER ON
2-minute Delay
1. Compressor start-up
. Condenser fan start-up
3. Evaporator fan(s) on  
    (continuously)
Cycle Off (Cut-out 
temperature reached) 
[Minimum  minutes]
1. Compressor off
. Condenser fan off
3. Evaporator fan(s)
    cycles on and off
Continue as 
normal cycling
Cycle On (Cut-on 
temperature reached) 
[Minimum  minutes]
1. Compressor start-up
. Condenser fan start-up
3. Evaporator fan(s) on  
 
    (continuously)
Defrost Start
Preprogrammed time interval
1. Compressor off
. Evaporator fan(s) off
3. Condenser fan off
4. Defrost heater on
5. "dF" displayed
Defrost End
Defrost thermistor 
reaches defrost 
termination temperature, 
or defrost timer reaches 
1 hour
Defrost heater off