5
c) Cabinet Temperature Correction (calibration factor)
In cases where there is a discrepancy between the actual cabinet center temperature 
and the displayed temperature for a particular model, a calibration factor is used to 
correct the displayed temperature.
WARNING
This unit has been factory tested with the default settings listed. Avoid using 
this function except to confirm that the setting is correct. If set incorrectly, the 
display could show an acceptable temperature even though the temperature 
is out of the proper range. This value should only be changed after consulting 
with the factory.
To view the current value, follow the steps below.
1) Turn the power on while pressing the  
 up button. The current correction calibration 
factor will be shown. If "18" is displayed, the value is 1.8°F (1.0°C). See the table below 
for the default values.
) If it is determined through discussion with the factory that the setting needs to be 
changed, press the 
 up or 
 down button to increase or decrease the value.
3)  Press the 
 button to save the new value.
4) Turn the power off and then back on. The unit will start running with the new value.
[Example]
When the average cabinet temperature is 5.4°F 
(3.0°C) higher than the thermistor detected 
temperature, change the correction calibration 
factor to 5.4°F (3.0°C).
Cabinet Temperature Correction (Calibration Factor)
Default
Model
Setting Range
1-Section
2-Section
3-Section
Refrigerator 
-9.9 to 9.9
°
F in 0.9
°
F increments  
(-9.5 to 9.5
°
C in 0.5
°
C increments)
00 (0.0
°
F) 
(00 (0.0
°
C))
36 (3.6
°
F) 
( 0 (.0
°
C))
Freezer 
18 (1.8
°
F) 
(10 (1.0
°
C))
45 (4.5
°
F)
(5 (.5
°
C))